20
JO
NIX
duct
07
08
MIN
3 mm
09
Fig. 07: Wash the mesh under running hot
water and dry it thoroughly with a cloth.
Do not put back the mesh on
the ionising tube if it is even
partially wet.
Fig. 08: Put the outer metal mesh back on
the glass tube so that it fully overlaps the
internal plate.
In any case ensure a minimum
distance of at least 3 mm from
the base of the tube.
Fig. 09: Gently screw the ionising tube
holding on to the base (green part).
If the operation is difficult to perform, pull
slightly the earthing spring so that it is not in
contact with the surface of the tube.
ATTENTION: do not overtighten the screw
after reaching its end stop.
Check that the earthing spring
is in contact with the outer
mesh once the ionising tubes
have been screwed back into
place. Otherwise contact the
manufacturer.
Summary of Contents for duct 70MIC2C
Page 30: ...30 JONIXduct NOTES...
Page 31: ......