25
ENGLISH
07.5 EXAMPLE OF INSTALLED AND CLAD FIREPLACE
To allow boiler expansion the cladding must always be separated from the steel fireplace by 2 to 3 mm.
NOTE
It is compulsory to foresee inspection hatches in the cladding for servicing and, in the combined models
(Wood/Pellet) to load the pellets.
WARNING
1. Fume exhaust
2. Air recirculating grid 400x100 mm (100 mm from
the ceiling) (MANDATORY)
3. Inspection door for pellet loading REQUIRED.
(refer to the ATTENTION box for details on
dimensions)
4. Pellet hopper
5. Door
6. Inspection door REQUIRED for burner group.
(refer to the ATTENTION box for details on
dimensions)
7. Combustion air intake ducting (see par 07.3 or
07.4)
8. Burner JOLLY MEC
9. Air recirculating grid 400x100 mm (50 mm from
the floor) (MANDATORY)
10. Ash pan
11. Door handle
12. Lifting hook
13. Adjustable vents for hot air 180x120mm
14. Flexible aluminium pipes for hot air ducting
(Ø100 mm)
15.
Humidifier coupling (right or left)
1
2
3
4
5
6
11
9
10
9
8
7
2
13
12
14
15
M
andatory
openings
FOGHET MODEL
DOOR
wood
&
pellet
pellet
loading
opening
aCCeSS to tHe
BURneR
CoRneR
:
wallS
:
The measurements in cm refer to the sizes of the holes to make
in the plasterboard in order to fasten our hatches in place.