14
All appliance tests, final inspection and fine-tuning was performed using the recommended certified pellets.. Jolly
Mec Caminetti S.p.A. is not responsible for malfunctions, breakdowns or problems due to the use of pellets that are not
recommended, as combustion parameters vary according to the quality of the pellets.
To achieve best operational results, it may be necessary to change the default factory settings on the control unit during
the optional Commissioning service. These operations must only be performed by a specialised Technical Service Center.
WARNING
CHAP.06 TECHNICAL DATA
06.1 HOMOLOGATION
Technical specifications resulting from laboratory tests conducted according to EN 14785, EN 13229 and EN13240 test methods at the
CERTIFICATION institute.
Description
Foghet EVO
Aria P 6,5 kW
Foghet EVO
Aria L 7,5 kW
Foghet EVO
Aria P 9,5 kW
Foghet EVO
Aria L 9 kW
Foghet EVO
Aria P 13 kW
Foghet EVO
Aria L 12 kW
UM
RFE Aria P
6,5 kW
RFE Aria L
7,5 kW
RFE Aria P
9,5 kW
RFE Aria L
9 kW
RFE Aria P
13 kW
RFE Aria L
12 kW
Combustible
Pellet
Legna
Pellet
Legna
Pellet
Legna
-
Burned power
7,37
8,60
10,61
11,26
15,47
14,05
kW
Rated heat output
6,58
7,57
9,55
9,62
13,65
12,06
kW
Fuel hourly consumption at rated heat output
1,508
2,02
2,173
2,646
3,168
3,301
kg/h
Reduced heat output
3,77
-
3,77
-
3,77
-
kW
Fuel hourly consumption at reduced heat output
0,883
-
0,883
-
0,883
-
kg/h
Space heating output
6,58
7,57
9,55
9,62
13,65
12,06
kW
Efficiency at rated heat output
89,39
88,0
90,0
85,39
88,21
85,79
%
Efficiency at reduced heat output
87,32
-
87,32
-
87,32
-
%
Rated voltage/frequency
230 / 50
V/Hz
Electrilcal absorption (combined) min-max
125/420
- / 85
130/420
- / 85
140/420
- / 85
W
Total weight
230
kg
Standard hopper capacity
41
-
41
41
kg
Flue draught
10
Pa
Fume exhaust diameter
180
mm
Average
flue gas temperature at rated heat output
152,0
141,7
167,7
178,0
218,6
190,2
°C
Flue gas temperature at reduced heating output
125,0
-
125,0
-
125
-
°C
CO (13% O
2
) at rated heat output
81,5
1242,2
105,6
779,3
32,6
604,0
mg/m
3
CO (13% O
2
) at reduced heat output
556,0
-
556,0
-
556,0
-
mg/m
3
CO
2
at rated heat output
9,24
8,75
11,11
9,03
12,90
10,10
%
CO
2
at reduced heat output
5,97
-
5,97
-
5,97
-
%
NO
x
(13% O
2
)
139,3
156,1
131,2
150,9
157,6
163,3
mg/m
3
OGC (13% O
2
)
23,2
67,5
5,3
61,2
4,3
44,2
mg/m
3
Flue gas mass flow at rated heat output
5,4
7,2
6,6
9,2
8,4
10,4
g/s
Flue gas mass flow at reduced heat output
4,8
-
4,8
-
4,8
-
g/s
Dust (13% O
2
) at rated heat output
11,7
18,5
14,9
26,4
23,2
32,2
mg/m
3
Maximum load
-
1,7
-
2,2
-
2,6
kg
Minimum air distance from inflammable side wall
200
mm
Minimum air distance from inflammable rear wall
100
mm
Minimum frontal air distance from inflammable material
1000
mm
Note:
This device can not be used with shared flues.
Recommended fuels:
for a list of recommended fuels, please see
CAP.06.2 - RECOMMENDED FUELS.