17
CHAP.04 - TECHNICAL DATA
04.1 HOMOLOGATION EN 14785
Recommended fuels:
PELLETS:See pellet characteristics indicated in
par. 04.2
on the following page
All tests, trials and fine-tuning done on the stove have been done with the recommended pellets.
JOLLY MEC CAMINETTI SPA is not responsible for malfunctions, breakdowns or problems due to the
use of pellets that are not recommended, as combustion parameters vary from pellet to pellet (they can
vary as much as approximately 30%). For optimal functioning, a fine-tuning on the combustion must oblig-
atorily be done with the control unit.
353
Burning output
Q
tot
12,05 17,91
kW
366
Nominal heat output
P
10,38 15,51
kW
360
Power given to fluid
P
w
8,04 13,54
kW
362
Minimum output
2,5 2,5
kW
302
Maximum output consumption
B
t
2,76 3.66
Kg/h
304
Minimum output consumption
0,5 0,5
Kg/h
357
Maximum output disposed of in the environment
P
sh
2,34 1,97
kW
053
Efficiency
η
86,19 86,57
%
601
Rated voltage/frequency
230/50 230/50
V/Hz
602
Electrical absorption min (in steady) - max (by lighting)
180 - 400 190 - 420
W
253
Total weight
115 130
Kg
401
Standard hopper capacity
18 30
l
702
Minimum uptake
12 12
Pa
653
Fume exhaust diam.
80 80
mm
106
Average fume T
t
a
199 208
°C
003
CO (13% O
2
)
0.015 0.006
%
006
CO
2
10,65 10,86
%
203
Fume mass
m
7,92 10,47
g/s
701
Inflammable materials distance
300 300
mm
990
Percentage of output ductible to other rooms
- 60-80
%
992
Diameter pipe for ducting air
- 80
mm
654
Combustion air pipe Ø
60 60
mm
Description
10 kW 15 kW
UM
Use of any type of liquid fuel is forbidden.
These or similar materials may be: dangerous for the user, damage the fireplace,
the fume exhaust union, the flue and pollute nature.
!
The chart's technical data was derived from certified data according to EN 14785
test methods.
The declared output may vary according to fuel type.
!