32
CHAP.07 - USAGE AND MAINTENANCE FOR THE USER
07.3 EMERGENCY CONSOLE
If the remote control breaks down, the basic functions can
be accessed by an emergency console (see also
"REMOTE CONTROL MANUAL M10-P AIR"
attachment),
located on the backside of the stove; detach the emergency
console attached by hook and press the interested buttons.
07.4 SAFETY THERMOSTAT PELLET TANK WITH MANUAL RESET
The fan begins to run automatically following the smokes tem-
peratures
The humidifying water (max capacity 1/2 litre) must be manual-
ly inserted in the stove through the filling window that is located
to the right of the fireplace, beneath the air diffusion grid (the
humidifier is full when the water reaches the level). Do remem-
ber that the stove can also operate without water.
Air humidificaton prevents physiological disorders such as: dry
throat, migraine, various allergies and excess dust caused by
environments that are too dry. Aromatic essences can be added
to the humidifier water (mixed with the water that has been
poured) to scent the rooms.
NEVER RUN THE STOVE WITHOUT ELEC-
TRICAL CURRENT AND WITH FUELS
OTHER THAN WOOD PELLETS OR WITH
INFLAMMABLE LIQUID
DO NOT TOUCH the parts of the fireplace
without cladding, excluding the handles
and the regulating controls, as they are
subject to high temperatures.
The room where the fireplace is installed
must not directly adjoin multi-floored stair-
wells; there must not be other boilers,
stoves or air extractors in the same room
(excluded of the type "C" according to
UNI 10683). An external air intake Ø80 mm
in the room is obligatory.
07.5 RECOMMENDATIONS AND WARNINGS
If the stove is turned off by the intervention of the safety thermostat, the
cause could be too high output . Decrease the output .
Proceed as follows to restore the stove's normal operation:
1
) wait until the stove is completely cold (10-20 minutes);
2
) reset the thermostat unscrewing the hood (
A
) located on the back-
side of the stove (photo alongside) and press the appropriate button
3
) refit the hood, reset the alarm on the control unit and start up again.
Only use original spare parts; original spare parts are available
through authorised retailers, authorised Assistance Centres, or
directly from JOLLY-MEC.
If the glass becomes very dirty (with visible blackening) while
operating on pellets, the causes could be:
• Little uptake in the flue (clean the flue or check its character-
istics).
• Insufficient comburent air (add more air with the combustion
fan), clean the air intake.
A
Back side of
the10KW stove.
The 15 kw stove
is similar(see
par.
04.5
)