42
Speed Control Issue
Start PWM max test (firmware setup screens), wait
20 seconds or until speed stabilizes
N
Y
Problem Fixed
Run Auto Calibration (firmware setup)
N
Y
OK
Measure speed and compare to value displayed in
time window
Speed feedback issue
Perform steps in order listed until problem resolved.
1.
.Ensure belt and drive is able to turn freely and are
properly mechanically connected.
2.
.Check all electrical connections
3.
.Verify reliance drive settings
4.
.Replace ribbon cable with a known good cable
5.
.Replace interface PCB with a known good PCB
6.
.Replace console PCB with a known good PCB
N
Y
Belt moving
See belt drive issue
Done
CORRECTIVE ACTION PROCEDURES – Speed Control Issues