Document Number: SE00458000-00
Page 28
6.2.
AN EXAMPLE FOR DEFINING THE EOP
FOR AB7 DRIVER IN VACUUM
ENVIRONMENT
An example for using Figure 13 and table 6 for the AB7 Driver:
An example vacuum application requires 15N at a velocity of 100mm/sec.
point of operation corresponds to the curve
d
for SE8 motor.
d
and a vacuum environment require that a duty cycle of 17% will not be
exceeded and the maximum continuous operation time is limited to 72 seconds.