95
Domestic air conditioner
Removal of procedure
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
2. Remove the horizontal
blade.
The horizontal blade is
single.
Installation procedure
1. Since key pattern hook is
provided, rotate the blade
and fit it to the left pivot first.
2. Fit the blade to the right
pivot.
3. Fit the blade to the center
pivot.
1
Release the center
pivot.
2
Bend the horizontal
blade slightly and
remove it.
blade
YJHJZH024BARRAFX
-SM
Summary of Contents for YJHJXH024BARR-FX