7.3.8 Communication error between the indoor and outdoor units
,QGRRUGLVSOD\ (
˗
2XWGRRU
:
GLVSOD\
˖
LED1 flash 15 times
0HWKRGRI
The date received from the another unit in indoor unit-outdoor unit signal
transmission is
0DOIXQFWLRQ
checked whether is normal
Detection
Malfunction
When the date sent from the another unit cannot be received normally,or when the content
Decision
of the data is abnormal
Conditions
Supposed
Ƶ
indoor unit- outdoor unit signal transmission error due to wiring error
Causes
Ƶ
Faulty PCB
7URXEOHVKRRWLQJ &DXWLRQ
Be sure to turn off power switch before connect or disconnect connector,
or else parts damage may be occurred.
NO
˄
A
˅
Restart the a/c and it
becomes normally.
If starting up normally, but
malfunction occurs again
after a while
Check whether the linking cable
between the indoor and outdoor
is well connected or whether its
core wires are well insulated.
Yes
Yes
Yes
No
No
The outdoor mainboard needs
dehumidification.
The outdoor mainboard
needs dedust.
1. Reconnect the linking cable;
2. Replace the linking cable with
new one.
YJHJZH024BARRAFX
-SM
Summary of Contents for YJHJXH024BARR-FX
Page 44: ...1 6 2 1 The Instruction For AS24GS1ERA YJHJZH024BARRAFX SM...
Page 82: ...79 Domestic air conditioner Installation WARNING CAUTION YJHJZH024BARRAFX SM...
Page 83: ...80 Domestic air conditioner Installation YJHJZH024BARRAFX SM...
Page 86: ...Installation 83 Domestic air conditioner YJHJZH024BARRAFX SM...
Page 87: ...Installation 84 Domestic air conditioner YJHJZH024BARRAFX SM...
Page 88: ...Installation 85 Domestic air conditioner YJHJZH024BARRAFX SM...
Page 91: ...88 Domestic air conditioner Installation YJHJZH024BARRAFX SM...
Page 92: ...e g 1U18FS1ERA 89 Domestic air conditioner Installation YJHJZH024BARRAFX SM...
Page 123: ...The end YJHJZH024BARRAFX SM...