![Johnson Controls RJ H Series Installation Operation & Maintenance Download Page 11](http://html1.mh-extra.com/html/johnson-controls/rj-h-series/rj-h-series_installation-operation-and-maintenance_2024194011.webp)
9
RJ SERIES INSTALLATION MANUAL
Horizontal Dimensional Data
C
Q
S
T
AIR COIL
B
1.8(4.6 cm)
B
T
R
R
S
Q
C
AIR COIL
N
PS
M
LS
M
PS
N
LS
FR
O
NT
FR
O
NT
FR
O
NT
FR
O
NT
H
5
FRONT
FRONT
END DISCHARGE
SIDE DISCHARGE
END DISCHARGE
SIDE DISCHARGE
CONDENSATE
1/2" PVC (009-012)
3/4" PVC (015-072)
CONDENSATE
1/2" PVC (009-012)
3/4" PVC (015-072)
Legend
FILTER RACK CONNECTION
2ft [61cm]
Service Access
H
2.1˝
[5.3 cm]
2.1˝
[5.3 cm]
Optional 2´ [61cm]
Service Access
Optional 2´ [61cm]
Service Access
5
LEFT RETURN
RIGHT RETURN
FILTER RACK CONNECTION
I
J
K
D
E
F
G
1.9(4.8 cm)
1.9(4.8 cm)
A
POWER SUPPLY
3/4" KNOCKOUT
LOW VOLTAGE
1/2" KNOCKOUT
LOW VOLTAGE
1/2" KNOCKOUT
1
2
3
4
U
V
Front
Air Handler Section
Compressor Section
W
X
AP
CP
AP
CMP
BP
BP
AP
CMP
CMP
AP
AP = Alternate Service Panel
BP = Blower Service Panel
CP = Control Access Panel
CMP = Compressor Service Panel
CP
LEFT RETURN END DISCHARGE
RIGHT RETURN END DISCHARGE
LEFT RETURN SIDE DISCHARGE
RIGHT RETURN SIDE DISCHARGE
RIGHT RETURN RIGHT VIEW
LEFT RETURN LEFT VIEW
FRONT VIEW
UNIT HANGER DETAIL
Blower
Outlet
Blower
Outlet
BP
Blower
Outlet
N
O
2.9(7.3 cm)
Ai
r C
oi
l S
id
e
Fi
lte
r R
ac
k
A
L
M
C
2.1
(5.3 cm)
H
BP
A
O
N
L
M C
2.9 (7.3 cm)
2.1
(5.3 cm)
H
Ai
r C
oi
l S
id
e
Fi
lte
r R
ac
k
Blower
Outlet
Horizontal
Models
Overall Cabinet
Water Connections
Electrical Knockouts
Discharge Connection
duct flange installed (±0.10 in)
Return Connection
using std deluxe filter rack
(±0.10 in)
Unit Hanger Dimensions
1
2
3
4
5
I
1/2”
cond
J
1/2”
cond
K
3/4”
cond
A
B
C
D
E
F
G
H
Loop
Water
FPT
HWG
FPT
L
LS
M
N
O
PS
Q
R
S
T
U
V
W
X
Width Depth Height*
In
Out
HWG
In
HWG
Out
Cond-
ensate
Low
Voltage
Ext
Pump
Power
Supply
Supply
End
Supply
Side
Supply
Height
Supply
Width
Supply
Side
Return
Depth
Return
Width
009-
012
in.
22.5
44.0
17.3
2.3
5.3
11.9
14.9
0.8
1/2 in.
N/A
3.8
9.7
11.7
5.9
7.4
7.3
9.7
5.8
7.3
17.9
14.6
0.5
0.4
44.8
25.1
21.0
21.4
cm.
57.2
111.8
43.9
5.8
13.5
30.2
37.8
2.1 12.7 mm
9.7
24.6
29.7
15.0
18.8
18.5
24.6
14.7
18.5
51.6
41.7
1.3
1.0
113.7
63.7
53.3
54.4
015-
018
in.
22.5
53.0
19.3
2.3
5.3
13.8
16.8
0.8
3/4 in. 1/2 in.
5.9
11.6
13.6
7.0
7.0
10.5
9.5
8.2
8.3
21.8
16.5
1.0
0.6
53.8
25.1
25.0
21.4
cm.
57.2 134.6 49.0
5.8
13.5
35.1
42.7
2.1 19.1 mm 12.7 mm 14.9
29.5
34.5
17.8
17.8
26.7
24.1
20.8
21.1
55.4
41.9
2.5
1.5
136.5 63.7
63.5
54.4
022-
030
in.
22.5
63.0
19.3
2.3
7.3
13.5
16.5
0.8
3/4 in. 1/2 in.
5.9
13.7
15.7
6.5
6.5
10.5
9.4
6.5
5.8
30.5
16.5
1.5
1.4
63.4
24.8
N/A
21.1
cm.
57.2 160.0 49.0
5.8
18.5
34.3
41.9
2.1 19.1 mm 12.7 mm 14.9
34.7
39.8
16.6
16.6
26.5
23.8
16.5
14.7
77.3
41.9
3.8
3.6
161.0 63.0
53.6
036-
038
in.
25.5
72.0
21.3
2.2
7.2
15.8
18.8
0.8
1 in. 1/2 in.
5.9
13.7
15.7
4.9
4.9
13.6
13.2
4.6
6.8
35.5
18.7
2.8
1.3
72.4
27.8
29.3
24.1
cm.
64.8 182.9 54.1
5.6
18.3
40.2
47.8
2.1 25.4 mm 12.7 mm 14.9
34.7
39.8
12.4
12.4
34.6
33.5
11.6
17.3
90.0
47.5
7.1
3.3
183.9 70.6
74.4
61.2
042-
049
in.
25.5
77.0
21.3
2.2
7.2
15.8
18.8
0.8
1 in. 1/2 in.
5.9
13.7
15.7
4.9
4.9
13.6
13.2
4.6
6.8
40.5
18.5
2.8
1.3
77.4
27.8
29.3
24.1
cm.
64.8 195.6 54.1
5.6
18.3
40.2
47.8
2.1 25.4 mm 12.7 mm 14.9
34.7
39.8
12.4
12.4
34.6
33.5
11.6
17.3 102.7 47.0
7.1
3.3
196.6 70.6
74.4
61.2
060-
072
in.
25.5
82.0
21.3
2.2
7.2
15.8
18.8
0.8
1 in. 1/2 in.
5.9
13.7
15.7
4.9
4.9
13.6
13.2
4.6
6.8
45.5
18.5
2.8
1.3
82.4
27.8
29.3
24.1
cm.
64.8 208.3 54.1
5.6
18.3
40.2
47.8
2.1 25.4 mm 12.7 mm 14.9
34.7
39.8
12.4
12.4
34.6
33.5
11.6
17.3
115.4
47.0
7.1
3.3
209.3 70.6
74.4
61.2
3/12/10
Horizontal unit shipped with deluxe 1 in. (field adjustable to 2 in.) duct collar/filter rack extending from unit 2.88 in. and is suitable for duct connection.
Discharge flange is field installed and extends 1 in. (25.4 mm) from cabinet.