 JCI FMS-1655

The Next Generation in Critical Airflow Controls 

CMS-1655 Central Monitoring Station  

Installation and Programming Manual

 

LB-CMS1655-S  

LB-CMS1655-T

Code No. LIT-12013121, Rev. A

Issued August 2018

Refer to the QuickLIT website for the most up-to-date version of this document.

This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 

15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference 

when this equipment is operated in a commercial environment. This equipment generates, uses, and can radiate 

radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause 

harmful interference to radio communications. Operation of this equipment in a residential area may cause harmful 

interference, in which case users will be required to correct the interference at their own expense.

Application

These installation instructions guide the installer through the installation of the CMS-1655 Central Monitoring Station.

Please read these instructions thoroughly before beginning installation. 

North American Emissions Compliance

United States

Canada

Installation

This Class (A) digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment 

Regulations.

Cet appareil numérique de la Classe (A) respecte toutes les exigences du Règlement sur le matériel brouilleur du 

Canada.

IMPORTANT

: The CMS-1655 Central Monitoring Station must be wired to 24 VAC only. Wiring the unit 

to 110 VAC will cause serious damange and void the warranty. 

Risk of Property Damage.

 

Ensure that the power source conforms to the requirements of the equipment. Failure to use a correct power 

source may result in permanent damage to the equipment.

Risque de dégâts matériels.

 

S’assurer que la source d’alimentation électrique est conforme aux spécifications de l’équipement. L’utilisation 

d’une source d’alimentation électrique inappropriée risque d’endommager irrémédiablement l’équipement.

NOTICE

NOTICE

Use of the software that is in (or constitutes) this product or access to the cloud or hosted services applicable to 

this product, if any, is subject to applicable terms set forth at www.johnsoncontrols.com/techterms.  Your use of this 

product constitutes an agreement to such terms.  If you do not agree to be bound by such terms, you may return 

the unused product to your place of purchase

.

Summary of Contents for CMS-1655

Page 1: ...ore beginning installation North American Emissions Compliance United States Canada Installation This Class A digital apparatus meets all the requirements of the Canadian Interference Causing Equipmen...

Page 2: ...655 to Nearest JCI Controller 7 Notes 8 PROGRAMMING MANUAL Introduction 9 Main Setup Menu 9 Unit Setup 10 Configuring Monitor Settings 10 Configuring Audible Alert Settings 11 System Setup 12 Configur...

Page 3: ...5 or by separate power supply 18 to 32 Vdc Touchscreen User Interface LCDSizeandType 3 2 diagonal transmissive Resolution 240 pixels x 320 pixels portrait mode Viewing Area 50 60 mm x 66 80 mm Color D...

Page 4: ...parameter is within defined normal operating limits Yellow indicates that the monitored parameter has drifted outside of the normal operating limits and is approaching the alarm region Red indicates t...

Page 5: ...tainless steel faceplate of the CMS 1655 Run the 4 conductor dual twisted pair electrical connection from the nearest FMS 1650 55 or HMS 1650 55 Refer to the wiring diagram shown on page 7 for details...

Page 6: ...wn on page 7 for details 6 Terminate the interface cable originating from the host controller at the 4 position and 3 position terminal blocks on the back side of the CMS 1655 display ensuring proper...

Page 7: ...used to indicate that a door is open at a monitored FMS unit if a door switch has been incorporated with the FMS A red background with the red exclamation point action icon indicates that the monitor...

Page 8: ...four parameters of up to four independent JCI controllers Once the individual controllers have been specified the parameters at each monitored controller may be selected This is accomplished by tappin...

Page 9: ...tandard view is selected may be adjusted either by using the hotspots on the main display or by selecting Display Setup Set Time Date The CMS 1655 is also designed to request time and date settings pe...

Page 10: ...N7 CN3 NETWK NETWK GND V FMS or HMS Backplane Connections Daisy chain together the SUB_NETs on the backplanes of all the FMS 1655 and or HMS 1655 units that will be monitored by the CMS 1655 Connect t...

Page 11: ...improvement TRIATEK reserves the right to change product specifications without notice Due to continuous improvement JCI reserves the right to change product specifications without notice INSTALLATIO...

Page 12: ...ed Menu screens time out after 90 seconds of inactivity while configuration screens automatically time out after 60 seconds This prevents unauthorized access to the user menu system should a unit be i...

Page 13: ...e CMS 1655 Single Station Monitor should be selected if a single controller is being monitored If multiple parameters at a single station need to be monitored then the monitor mode should be specified...

Page 14: ...lected After selecting the specific stations which should activate the audible alarm when the alarm status occurs pressing the Next button invokes the next configuration screen as shown in Figure 19 w...

Page 15: ...e configuration settings associated with the CMS 1655 alarm facility may be accessed at the Alarms Setup menu shown in Figure 22 Options on this menu allow individual alarms to be enabled for each of...

Page 16: ...missioned mode is selected at a monitored HMS 1650 55 These modes are indicated by an action icon represented as a red circle with a line through its center The Safety Halo status indicator if enabled...

Page 17: ...ormal operating hours if Nightly Auto Dim is enabled or continuously otherwise To configure the Safety Halo feature to reduce in brightness intensity during evening hours or otherwise select the Night...

Page 18: ...uld be entered as a two digit entry For convenience the time and date may also be entered directly from the main screen Single Station Monitor mode only by tapping the time and date fields respectivel...

Page 19: ...een made to the network parameters subnetwork address Selecting this option invokes the warning message as shown in Figure 31 informing the user that the CMS 1655 will be reset when the OK button is t...

Page 20: ...Due to continuous improvement JCI reserves the right to change product specifications without notice User Menu Flow Diagram 17 PROGRAMMING MANUAL...

Page 21: ...The Next Generation in Critical Airflow Controls CMS 1655 Central Monitoring Station Installation and Programming Manual LB CMS1655 S LB CMS1655 T Code No LIT 12013121 Rev A Issued August 2018 Refer...

Reviews: