5.9.3 Setting of “
Floor HEAT Control
” (Radiation Sensor during Heating Operation)
(1) Function
If a steep temperature difference is detected between the radiation temperature and the setting
temperature, this function heats the entire room efficiently by adjusting airflow direction and airflow
volume.
(2) Descriptions for Setting Items:
The setting of “Floor HEAT Control”
• OFF: This function is unavailable.
• ON: This function is available.
(The default setting is OFF.)
(3) Supplement of Function
• When this function is activated, airflow direction is directed downwards and the airflow volume
changes to “AUTO”.
• This function continues to be active for 20 to 60 minutes, depending on the difference between the
ambient air temperature and the set temperature.
• This function will repeat, depending on the temperature difference between a radiation temperature
and the setting temperature.
HIGH
LOW
● If the radiation temperature (Floor Temperature) in the detecting area is low, this function may be activated
frequently.
● This louver direction is downward during this function. Avoid a cold draft from a direct airflow by setting
function “Individual Louver Setting” or “Avoid Air”.
● During the activation of this function, “Floor HEAT control” is indicated on the LCD.
If two wired controllers are utilized, the comfort setting is available by using the wired controller 1 only.
The swing louver direction can be varied according to each set function. If the set airflow direction is not
comfortable, refer to the following descriptions and adjust the airflow direction.
Order of Priority for Setting the Swing Louver Direction
● Capacity save operation (Function 1) set as “Motion Sensor Setting”.
● Setting of “Individual Louver Setting”
● Swing louver direction at detecting human activity side by “Avoid Air” and “Receive”
function.
● Setting of “Floor HEAT Control”
● Louver direction set on the main menu of a wired controller.
5.9.4 Useful Tips on Setting the Swing Louver Direction