background image

ii 

TC-19001

1. Safety Summary

Signal Words

 

Indicates a hazardous situation that, if not avoided, could result in death or serious injury.

Indicates a hazardous situation that, if not avoided, could result in minor or moderate injury. 

Indicates information considered important, but not hazard-related (for example, 
messages relating to property damage).

General Precautions

To reduce the risk of serious injury or death, read these instructions thoroughly and 
follow all warnings or cautions included in all manuals that accompanied the product 
and are attached to the unit. 

Refer back to these safety instructions as needed.

 

This system, including this central controller, should be installed by personnel certi

fi

 ed by Johnson Controls, 

Inc. Personnel must be quali

fi

 ed according to local, state and national building and safety codes and 

regulations. Incorrect installation could cause leaks, electric shock, 

fi

 re or an explosion. In areas where 

Seismic Performance requirements are speci

fi

 ed, the appropriate measures should be taken during installation 

to guard against possible damage or injury that might occur in an earthquake. 
If the unit is not installed appropriately, injuries may occur because of the falling unit.

 

Use appropriate Personal Protective Equipment (PPE), such as gloves, protective goggles and electrical 
protection equipment and tools suited for electrical operation purposes. 

 

When transporting, be careful while picking up, moving and mounting these units. 
Although the central controller may be packed using plastic straps, do not use them for transporting from one 
location to another. Do not stand on or put any material on the central controller. 

 

When installing the central controller cables to the units, do not touch or adjust any safety devices inside the indoor 
or outdoor units. All safety features, disengagement, and interlocks must be in place and functioning correctly 
before the equipment is put into operation. If these devices are improperly adjusted or tampered with in any way, a 
serious accident can occur. Never bypass, wire around, or jump-out any safety device or switch. 

 

Use only Johnson Controls recommended, provided as standardized, or replacement parts.

 

Johnson Controls will not assume any liability for injuries or damage caused by not following steps outlined or 
described in this manual.  Unauthorized modi

fi

 cations to Johnson Controls products are prohibited as they…

 

May create hazards which could result in death, serious injury or equipment damage; 

 

Will void product warranties; 

 

May invalidate product regulatory certi

fi

 cations;

 

May violate OSHA standards;

Take the following precautions to reduce the risk of property damage.

 

Do not touch the main circuit board or electronic components in the controller or remote devices. Make sure that 
dust and/or steam does not accumulate on the circuit board.

 

When installing the unit in a hospital or other facility where electromagnetic waves are generated from nearby 
medical and/or electronic devices, be prepared for noise and electronic interference “Electromagnetic Interference 
(EMI)”.  Do not install where the waves can directly radiate into the electrical box, controller cable, or controller. 
Inverters, appliances, high-frequency medical equipment, and radio communications equipment may cause the 
unit to malfunction. The operation of the unit may also adversely affect these same devices. Install the unit at least 
10 ft. (approximately 3m) away from such devices.  

 

Locate the wireless controller at a distance of at least three feet (approximately 1m) between the indoor unit and 
electric lighting. Otherwise, the receiver part of the unit may have dif

fi

 culty receiving operation commands. 

Summary of Contents for CCXL01

Page 1: ...001 ENGINEERING MANUAL VRF Central Touchscreen Controller Engineering Manual VRF Central Touchscreen Controller CCXL01 VRF Central Touchscreen Controller Adapter CCXLA01 Energy Calculation Software CC...

Page 2: ......

Page 3: ...rovides common descriptions basic and advanced information to maintain and service this central controller which you operate as well for other models This manual should be considered as a permanent pa...

Page 4: ...or adjust any safety devices inside the indoor or outdoor units All safety features disengagement and interlocks must be in place and functioning correctly before the equipment is put into operation...

Page 5: ...and maintenance of the unit to the customer according to the information in all manuals that accompanied the system All manuals and warranty information must be given to the user Electrical Precautio...

Page 6: ...cables Secure the suspended cables at regular intervals but not too tightly Make sure that the terminals do not come into contact with the surface of the electrical box If the terminals are too close...

Page 7: ...NTS 1 System Summary 1 1 2 System Specification 2 1 2 1 Features 2 1 2 2 Example for System Configuration 2 4 2 3 Standard Specification 2 5 2 4 Appearance 2 6 IMPORTANT NOTICE AND SAFETY SUMMARY i 1...

Page 8: ...vi TC 19001...

Page 9: ...on day 1 5 summer winter regular 8 Displayed Item for Usage History Each of the following data of up to 2 years can be shown Accumulated operation time Accumulated thermo ON time Ave air intake temp A...

Page 10: ...ntral Controller Large Central Controller VRF Central Touchscreen Controller Outdoor Units Indoor Units Individual Remote Controllers Wired Controller Simplified Wired Controller IR Receiver Wireless...

Page 11: ...oller CIS01 Wireless Controller CIR01 IR Infrared Receiver Kit for 4 Way Cassette C4IRK01 IR Infrared Receiver Kit for 1 Way Cassette C1IRK01 IR Infrared Receiver Kit for Wall Mounted and Ducted CWDIR...

Page 12: ...system Central Controllers Mini Central Controller VRF Central Touchscreen Controller Large Central Controller Item H LINK II Max Number of Refrigerant Groups System 64 Address Setting Range of Indoor...

Page 13: ...2 Central Controller Configuration Example OK Menu Back Help ECO On Off A C MODE SPEED TEMP COOL LOUV Adj Meeting Room LOUV FLTR Motion Sensor ON Avoid OK Menu Back Help ECO On Off A C MODE SPEED TEMP...

Page 14: ......

Page 15: ...as an optional feature 5 Various information display styles Choose from panel layout list display depending on the number of controlled points and items to be monitored Panel Displays items that are f...

Page 16: ...Pump H Y VAHP_B21S Top Flow 208 230V Heat Pump Low Ambient Type H Y VAHP_B31CW Top Flow 460V Heat Pump Low Ambient Type H Y VAHP_B41CW Indoor Unit Ducted High Static H Y IDH_B21S H Y IDH_B22S Ducted...

Page 17: ...ntire system RC Group Registered on CCXL01 as a collection of indoor units up to 16 connected via RC control line Group Registered on CCXL01 as a collection of multiple RC groups altogether Block Regi...

Page 18: ...be available Controlling and monitoring on the system are all based on the clock on VRF Central Touchscreen Controller Correct operation may not be expected due to unnecessary clock setting change on...

Page 19: ...ication Specification Item Specification Communication Peer Indoor units Outdoor units 1 Communication Line Nonpolar Two Wires Communication Method Half Duplex Communication Synchronous Method Asynchr...

Page 20: ...YSTEM SPECIFICATION 2 6 TC 19001 2 4 Appearance Unit inch mm 14 5 8 372 1 1 4 32 5 H LINK External in output Wiring Port Power Input LAN Port SD Card Slot USB flash drive slot 1 1 8 27 8 8 15 16 227 2...

Page 21: ...via H LINK SW2 LCD power Switch RS 485 communication Yellow Currently not in use SW1 Power switch for embedded adapter POWER Green Lights while power is provided to VRF Central Touchscreen Controller...

Page 22: ...6 5 8 167 9 Screw Hole for Wall Mount H LINK External input output Wiring Port Power Input LAN Port 8 15 16 227 2 Rear View Screw Hole for Wall Mount 5 1 2 140 1 9 16 39 5 0 11 16 17 6 1 7 16 36 3 1 8...

Page 23: ...6 110 6 1 8 155 2 13 16 72 10 1 16 255 6 4 0 1 4 6 9 1 4 235 6 Status Indicator Power Button Power Line Port H LINK External in output and LAN Wiring Port Screw Hole for Wall Mount Remove rubber cover...

Page 24: ...2019 Johnson Controls Inc TC 19001 Code No LIT 12013165 Issued Feb 2019...