background image

TC-19001

 

i

Important Notice

 

Johnson Controls Inc. pursues a policy of continuing improvement in design and performance in its 
products.  As such, Johnson Controls Inc. reserves the right to make changes at any time without prior 
notice.

 

Johnson Controls Inc. cannot anticipate every possible circumstance that might involve a potential 
hazard.

 

This central controller is designed for VRF air conditioning applications only. 
Do not use this product for anything other than the purposes for which it was intended for.

 

The installer and system specialist shall safeguard against leakage in accordance with local pipe

fi

 tter 

and electrical codes. The following standards may be applicable, if local regulations are not available. 
International Organization for Standardization: (ISO 5149 or European Standard, EN 378).  No part of 
this manual may be reproduced in any way without the expressed written consent of Johnson Controls 
Inc.

 

This central controller is operated and serviced in North America and comes with a full complement of 
the appropriate Safety, Danger, Caution and Warnings.

 

If you have questions, please contact your distributor or contractor.

 

This manual provides common descriptions, basic and advanced information to maintain and service 
this central controller which you operate as well for other models.

 

This manual should be considered as a permanent part of the air conditioning equipment and should 
remain with the air conditioning equipment.

 

No part of this manual may be reproduced without the expressed written permission of Johnson 
Controls, Inc.

Product Inspection upon Arrival

1.  Upon receiving this product, inspect it for any damages incurred in transit. Claims for damage, either 

apparent or concealed, should be 

fi

 led immediately with the shipping company.

2.  Check the model number, electrical characteristics (power supply, voltage, and frequency rating), and 

any accessories to determine if they agree with the purchase order.

3.  The standard utilization for this unit is explained in these instructions.  Use of this equipment for 

purposes other than what it designed for is not recommended. 

4.  Please contact your local agent or contractor as any issues arise involving installation, performance, 

or maintenance arise. Liability does not cover defects originating from unauthorized modi

fi

 cations 

performed by a customer without the written consent of Johnson Controls, Inc.  
Performing any mechanical alterations on this product without the consent of the manufacturer will 
render your warranty null and void.

Summary of Contents for CCXL01

Page 1: ...001 ENGINEERING MANUAL VRF Central Touchscreen Controller Engineering Manual VRF Central Touchscreen Controller CCXL01 VRF Central Touchscreen Controller Adapter CCXLA01 Energy Calculation Software CC...

Page 2: ......

Page 3: ...rovides common descriptions basic and advanced information to maintain and service this central controller which you operate as well for other models This manual should be considered as a permanent pa...

Page 4: ...or adjust any safety devices inside the indoor or outdoor units All safety features disengagement and interlocks must be in place and functioning correctly before the equipment is put into operation...

Page 5: ...and maintenance of the unit to the customer according to the information in all manuals that accompanied the system All manuals and warranty information must be given to the user Electrical Precautio...

Page 6: ...cables Secure the suspended cables at regular intervals but not too tightly Make sure that the terminals do not come into contact with the surface of the electrical box If the terminals are too close...

Page 7: ...NTS 1 System Summary 1 1 2 System Specification 2 1 2 1 Features 2 1 2 2 Example for System Configuration 2 4 2 3 Standard Specification 2 5 2 4 Appearance 2 6 IMPORTANT NOTICE AND SAFETY SUMMARY i 1...

Page 8: ...vi TC 19001...

Page 9: ...on day 1 5 summer winter regular 8 Displayed Item for Usage History Each of the following data of up to 2 years can be shown Accumulated operation time Accumulated thermo ON time Ave air intake temp A...

Page 10: ...ntral Controller Large Central Controller VRF Central Touchscreen Controller Outdoor Units Indoor Units Individual Remote Controllers Wired Controller Simplified Wired Controller IR Receiver Wireless...

Page 11: ...oller CIS01 Wireless Controller CIR01 IR Infrared Receiver Kit for 4 Way Cassette C4IRK01 IR Infrared Receiver Kit for 1 Way Cassette C1IRK01 IR Infrared Receiver Kit for Wall Mounted and Ducted CWDIR...

Page 12: ...system Central Controllers Mini Central Controller VRF Central Touchscreen Controller Large Central Controller Item H LINK II Max Number of Refrigerant Groups System 64 Address Setting Range of Indoor...

Page 13: ...2 Central Controller Configuration Example OK Menu Back Help ECO On Off A C MODE SPEED TEMP COOL LOUV Adj Meeting Room LOUV FLTR Motion Sensor ON Avoid OK Menu Back Help ECO On Off A C MODE SPEED TEMP...

Page 14: ......

Page 15: ...as an optional feature 5 Various information display styles Choose from panel layout list display depending on the number of controlled points and items to be monitored Panel Displays items that are f...

Page 16: ...Pump H Y VAHP_B21S Top Flow 208 230V Heat Pump Low Ambient Type H Y VAHP_B31CW Top Flow 460V Heat Pump Low Ambient Type H Y VAHP_B41CW Indoor Unit Ducted High Static H Y IDH_B21S H Y IDH_B22S Ducted...

Page 17: ...ntire system RC Group Registered on CCXL01 as a collection of indoor units up to 16 connected via RC control line Group Registered on CCXL01 as a collection of multiple RC groups altogether Block Regi...

Page 18: ...be available Controlling and monitoring on the system are all based on the clock on VRF Central Touchscreen Controller Correct operation may not be expected due to unnecessary clock setting change on...

Page 19: ...ication Specification Item Specification Communication Peer Indoor units Outdoor units 1 Communication Line Nonpolar Two Wires Communication Method Half Duplex Communication Synchronous Method Asynchr...

Page 20: ...YSTEM SPECIFICATION 2 6 TC 19001 2 4 Appearance Unit inch mm 14 5 8 372 1 1 4 32 5 H LINK External in output Wiring Port Power Input LAN Port SD Card Slot USB flash drive slot 1 1 8 27 8 8 15 16 227 2...

Page 21: ...via H LINK SW2 LCD power Switch RS 485 communication Yellow Currently not in use SW1 Power switch for embedded adapter POWER Green Lights while power is provided to VRF Central Touchscreen Controller...

Page 22: ...6 5 8 167 9 Screw Hole for Wall Mount H LINK External input output Wiring Port Power Input LAN Port 8 15 16 227 2 Rear View Screw Hole for Wall Mount 5 1 2 140 1 9 16 39 5 0 11 16 17 6 1 7 16 36 3 1 8...

Page 23: ...6 110 6 1 8 155 2 13 16 72 10 1 16 255 6 4 0 1 4 6 9 1 4 235 6 Status Indicator Power Button Power Line Port H LINK External in output and LAN Wiring Port Screw Hole for Wall Mount Remove rubber cover...

Page 24: ...2019 Johnson Controls Inc TC 19001 Code No LIT 12013165 Issued Feb 2019...

Reviews: