CONDENSATE PUMP & DRAIN TUBE
10.1
CONDENSATE PUMP
10.1.1
Supplied with 6 mm x 10 m condense tube. Condense adapter and 2 x
clips.
SAFETY NOTE:
If the pump fails, the safety float switch will shut off the heater
operation.
10.1.2 DO NOT HANDLE PUMP IN WET CONDITIONS OR WITH WET
HANDS
10.1.3
To reduce the risk of electric shock, ensure the electrical supply is per-
manently wired to earth.
10.1.4 TECHNICAL DATA
a)
Tank capacity : 0.5 L
b)
High level safety cut out
c)
Outlet size 6mm ID
d)
Maximum water temperature: 60 °C
e)
Maximum noise level: 21 dB(A) at 1 m
10.1.5
Where the tubing from the pump is connected directly to the soil stack
or waste pipe, there must always be either a waste trap after the
tubing connections, or a 75mm “U” trap formed within the tubing.
10.1.6
Where the tubing from the pump is connected to an external soil and
vent stack extra care is necessary to ensure that the condense pipe
could not be blocked through the condense freezing.
10.1.7
The tank pump uses small bore (6mm) flexible hose which can be
routed above or below doors, windows and under kitchen cabinets.
RESERVOIR
FLOAT
FILTER
FIGURE 11. CONDENSE PUMP
10.2 CONDENSE TUBE ROUTING OP-
TIONS
Option A. Routing to outside drain via sink
Option B. Routing to drain pipe via roof
Option C. Routing to bath waste
Option D. Routing under floor to sink waste
FIGURE 12. CONDENSATE ROUTING OPTIONS
B
C
D
A
NOTE:
7 m MAXIMUM
HEAD LENGTH OF
CONDENSE TUBE