13
Sales/Spares & Replacement Help Line 01604 762881
9.11 EXTENDED HORIZONTAL FLUE SYSTEM
Extended horizontal flue set up comprises of:
The required flue lengths up to a length of 10 m
800 mm Horizontal Terminal
90° Elbow
Inside Wall Cover Plate
Outside Wall Cover Plate
100 mm Diameter Clamp (1 per flue length)
OPTIONAL ROOF OUTLETS AVAILABLE
9.12
FLAT ROOF OPTION
The Flat Roof Collar.
9.13 PITCHED ROOF OPTION
A Pitched Roof Collar can be fitted on a pitched
roof with an angle of between 20° to 50° pitch.
9.14 RIDGE TERMINAL OPTION
The Ridge Terminal replaces a single 450 mm
ridge tile and connects to a vertical flue system.
FIGURE 8. OPTIONAL ROOF OUTLET
FIGURE 9. OPTIONAL ROOF OUTLETS
FIGURE 10. OPTIONAL ROOF OUTLETS
500mm
PITCHED
ROOF
WEATHER
COLLAR
500mm
FLAT ROOF
WEATHER
COLLAR
20˚
to 50˚
1140mm
1140mm
FIGURE 7. EXTENDED HORIZONTAL FLUE
HORIZONTAL
TERMINAL
VERTICAL
TURRET
EXTENSION
LENGTH
CLAMP
CLAMP
90° ELBOW
RIDGE
TERMINAL
CLAMPS
FLUE
EXTENSIONS
VERTICAL
APPLIANCE
ADAPTOR
ADJUSTABLE
LENGTH
Summary of Contents for WARMCAIR C26D