Technical data
Dimensions
Width
Height
Depth
450 mm
850 mm
610 mm
Electrical connection
Voltage
Overall power
Fuse
Frequency
220-240 V
2200 W
10 A
50 Hz
Water supply pressure
Minimum
Maximum
0.05 MPa (0.5 bar)
0.8 MPa (8 bar)
Capacity
Place settings
9
Installation
Warning!
It is dangerous to alter
the specifications or attempt to
modify this product in any way.
This appliance is heavy. Care should
be taken when moving it.
Care must be taken to ensure that
the appliance does not stand on the
electrical supply cable.
Any electrical work required to install
this appliance must be carried out by
a qualified electrician or competent
person.
Any plumbing work required to
install this appliance must be carried
out by a qualified plumber or
competent person.
Unpacking
• Remove all packaging before positioning
the machine.
• If possible, position the machine next to a
water tap and a drain.
Fitting under a counter
(Kitchen worktop or sink)
By removing the machine’s worktop, you
can install it under a close fitting sink unit or
a pre-existing top, providing the dimensions
of the recess correspond to those shown in
the picture.
Caution!
It is necessary to protect
the underside of the kitchen worktop
from condensation. A plastic top
cover can be purchased, contact your
local Service Force Centre.
29
Summary of Contents for JLDWW 906
Page 1: ...JLDWW 906 Dishwasher Instruction manual ...
Page 35: ...35 ...