Joerns Dolphin Fluid Immersion Simulation System User & Service Manual Download Page 20

Joerns Healthcare Warranty Program

  for Dolphin Fluid Immersion Simulation

®

 System Advanced Support Surfaces

Post Acute, Acute, HomeCare

 

2430 Whitehall Park Dr. Ste 100

Charlotte, NC 28273

(P) 800.826.0270

(F) 800.457.8827

VA/Government

19748 Dearborn Street

Chatsworth, CA 91311

(P) 800.966.6662

(F) 800.232.9796

Canadian Office

1000 Clarke Rd. Ste 6

London, ON Canada N5V 3A9

(P) 866.546.1151

(F) 519.451.8662

United Kingdom and  

Other Countries

+44 (0)844 811 1156

+44 (0)844 811 1157

Netherlands

+31 (0)30 6363700

+31 (0)30 6363799

www.joerns.com • email: [email protected]

© 2014 Joerns Healthcare • 6110109 RevG • 14-2640

Joerns Healthcare warrants the Dolphin FIS System 

advanced support surfaces to be sold free from 

defects in workmanship and materials, under normal 

and proper use, for a period of two (2) years on 

the advanced support surfaces, and two (2) years 

on the electromechanical mattress components 

(compressors, valves, printed circuit boards, hoses, 

and couplers). Damages arising from improper use will 

not be covered by this warranty. 

Improper use is defined as, but not limited to, those 

caused by:

•  Burns 

•  Use of improper chemical agents 

•  Needle punctures, cuts, or abrasions 

•  Excessive loads 

•  Staining 

•  Negligent or excessive usage 

•  Improper maintenance, handling and/or cleaning 

•  Failure to use in the manner indicated in the Dolphin 

FIS System user manual

Any modification, repair or alteration done to the 

Dolphin FIS System that was not authorized in writing 

by Joerns Healthcare will void this warranty.

Damage caused by use in unsuitable environmental 

conditions, abuse or failure to maintain the product in 

accordance with user and service instructions is not 

covered. 

This warranty is extended to the original purchaser of 

the equipment.

Parts

Joerns’ Dolphin FIS System contains various parts 

that wear from normal use. Joerns Healthcare’s 

obligation under this warranty is limited to supplying 

replacement parts, servicing or replacing, at its option, 

any product which is found by Joerns to be defective. 

When requested by Joerns, parts must be returned for 

inspection at the customer’s expense. Credit will be 

issued only after inspection.

Service

Most service requests can be handled by the facility 

Maintenance Department with assistance from the 

Joerns Healthcare Product Service Department. 

Most parts requested can be shipped next day air at 

the customer’s expense. 

Should a technician be required, one will be provided 

by Joerns Healthcare, at our discretion. Only the 

Joerns Healthcare Product Service Department can 

dispatch authorized technicians. 

Manufactured By:

Joerns Healthcare, LLC

2100 Design Road

Arlington, TX 76014

Summary of Contents for Dolphin Fluid Immersion Simulation System

Page 1: ...dvanced Surfaces Dolphin Fluid Immersion Simulation System Dolphin Pediatric Fluid Immersion Simulation System To avoid injury read user s manual before using Representative image of the Dolphin Fluid...

Page 2: ...y within the confines of the bed Do not let any extremities protrude over the side or between the bed rails when the mattress is being used Danger Explosion Hazard Do not use in the presence of flamma...

Page 3: ...for assessment and implementation of bed side rails in various health care settings Entrapment zones involve the relationship of bed components often directly assembled by the healthcare facility rath...

Page 4: ...pecialty Surface Wheelchair Cushion Troubleshooting 12 Therapy Surface Not Inflating Unable to Change Therapy Mode or Adjust Comfort Control Nursing Procedures 12 13 Recommended Linen Changing the The...

Page 5: ...on FIS System is an advanced therapy system designed to provide state of the art pressure redistribution by simulating the effects of a body immersed in a fluid medium The Dolphin System includes thre...

Page 6: ...bution technology designed to alleviate vertical shear forces The therapy mattresses and specialty surfaces conform to the specific shape of the patient minimizing soft tissue distortion reducing isch...

Page 7: ...ess that can fit any healthcare bed frame including bariatric frames up to 48 122 cm wide Conforms to specific shape of the patient minimizing soft tissue distortion reducing ischial tuberosity penetr...

Page 8: ...battery back up will provide power for continued therapy mattress system operation for approximately 12 hours Keyboard Functions Warning For important precautions see page two Caution The patient s he...

Page 9: ...d from further adjustments When locked pressing the Lock button again restores normal operation and the yellow LED is extinguished Battery Indicators Figure 4 The Battery indicator will blink when the...

Page 10: ...0 LED s and cover the full control range from Soft to Firm When operating within normal parameters the Auto Feedback LED scale will be amber Should the system be outside of normal parameters the LED s...

Page 11: ...e appropriate position based on the patient s clinical condition 2 Select the highest or most firm Comfort Adjust setting 3 Hand Check Place a hand with three 3 fingers if head of bed at 30 or higher...

Page 12: ...g on Battery Back up Ensure that the power is not on Standby If on Standby press the Power button Ensure that all air cells are connected Ensure that the Mode is in the appropriate position for the at...

Page 13: ...that the patient is positioned properly within the confines of the bed or other specialty item Do not let any extremities protrude over the side or between the bed rails when the mattress is being use...

Page 14: ...he therapy mattress or specialty surface deflated thoroughly wipe down entire mattress as air cells will lie flat Be sure to reach all areas underneath and in between air cells Allow to air dry If dus...

Page 15: ...retcher Pad Maximum weight capacity2 700 lbs 318 1 Kg Wheelchair Cushion Maximum weight capacity3 250 lbs 113 6 Kg Pediatric System Minimum weight capacity1 5 lbs 2 3 Kg Dimensions Control Unit 11 5 2...

Page 16: ...should be observed to verify normal operation in the configuration in which it will be used Guidance and Manufacturer s Declaration Electromagnetic Emissions The AutoVector Fluid Immersion Simulator...

Page 17: ...ospital environment Surge IEC 61000 4 5 1 kV line s to line s 2 kV line s to earth 1 kV line s to line s 2 kV line s to earth Mains power quality should be that of a typical commercial or hospital env...

Page 18: ...ation distance in metres m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference...

Page 19: ...ng to the maximum output power of the communications equipment Rated maximum output power of transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz...

Page 20: ...e Improper maintenance handling and or cleaning Failure to use in the manner indicated in the Dolphin FIS System user manual Any modification repair or alteration done to the Dolphin FIS System that w...