SECTION 3 - TROUBLESHOOTING
3-2
– JLG Sizzor –
3120826
Table 3-1. Platform Assembly - Troubleshooting
TROUBLE
PROBABLE CAUSE
REMEDY
No response to control switch
Enable switch not activated
Activate enable switch
Function not activated within the 3 seconds after
enable switch was depressed
Reactivate enable switch
Enable switch not functioning properly
Replace enable switch circuit card
Lift control switch inoperative
Repair or replace lift control switch
Hydraulic system oil low
Replenish oil as necessary
No power supply
See wiring diagram
Restricted or broken supply line on valve bank or
hydraulic pump
Clean, repair or replace line
Control valve not functioning properly
Repair or replace valve
Defective dump valve on cylinder
Repair or replace dump valve
Lift cylinder not functioning properly
Repair or replace lift cylinder
Hydraulic pump not functioning properly
Repair or replace hydraulic pump
Platform will not raise
Enable switch not activated
Activate enable switch
Function not activated within the 3 seconds after
enable switch was depressed
Reactivate enable switch
Enable switch not functioning properly
Replace enable switch circuit card
Load capacity exceeded. (Personnel and/or equip-
ment.)
Reduce load. (Refer to capacity placard.)
Hydraulic system oil low
Replenish oil as necessary
Broken or binding pivot pin
Repair or replace pivot pin
Restricted or broken hydraulic line or fitting
Clean, repair or replace line or fitting
Control valve not functioning properly
Repair or replace control valve
Lift cylinder not functioning properly
Repair or replace lift cylinder
Pump does not respond when lift control switch is
moved to the up position
Refer to electrical troubleshooting table
No electrical signal being sent to lift up control valve
cartridge
Refer to electrical troubleshooting table
Platform will not lower
Enable switch not activated
Activate enable switch
Function not activated within the 3 seconds after
enable switch was depressed
Reactivate enable switch
Enable switch not functioning properly
Replace enable switch circuit card
Pump does not respond when lift control switch is
moved to the down position
Refer to electrical troubleshooting table
No electrical signal being sent to lift down control
valve cartridge
Refer to electrical troubleshooting table
Lift down control valve cartridge not functioning
properly
Repair or replace lift down control valve cartridge
Lift cylinder not functioning properly
Repair or replace lift cylinder
Summary of Contents for 25RTS
Page 2: ......
Page 8: ...TABLE OF CONTENTS iv JLG Sizzor 3120826 This page intentionally left blank...
Page 11: ...SECTION 1 SPECIFICATIONS 3120826 JLG Sizzor 1 3 Figure 1 1 Torque Chart...
Page 12: ...SECTION 1 SPECIFICATIONS 1 4 JLG Sizzor 3120826 Figure 1 2 Lubrication Diagram...
Page 36: ...SECTION 2 PROCEDURES 2 20 JLG Sizzor 3120826 Figure 2 21 Pressure Adjustment Locations 2 W S...
Page 38: ...SECTION 2 PROCEDURES 2 22 JLG Sizzor 3120826 Figure 2 24 Pressure Adjustment Locations 4 W S...
Page 42: ...SECTION 2 PROCEDURES 2 26 JLG Sizzor 3120826 Figure 2 26 Piston Drive Motor...
Page 52: ...SECTION 2 PROCEDURES 2 36 JLG Sizzor 3120826 Figure 2 27 Drive Torque Hub 2WD 4WD Rear...
Page 56: ...SECTION 2 PROCEDURES 2 40 JLG Sizzor 3120826 Figure 2 28 Drive Torque Hub Brake 4WD Front...
Page 59: ...SECTION 2 PROCEDURES 3120826 JLG Sizzor 2 43 Figure 2 29 Drive Brake 2WD 2WS...
Page 64: ...SECTION 2 PROCEDURES 2 48 JLG Sizzor 3120826 This page left blank intentionally...
Page 82: ...SECTION 3 TROUBLESHOOTING 3 18 JLG Sizzor 3120826 This page intentionally left blank...
Page 83: ......