SECTION 5 - GENERAL SPECIFICATIONS AND MAINTENANCE
3121744
– JLG Lift –
5-29
4424
POWER MODULE VOLTAGE TOO LOW -
MODULE SHUTDOWN
None
4_4
• DriveState = PREVENTED
• LiftUpState = PREVENTED
• Severe B+ Undervoltage
Set:
Capacitor bank voltage
dropped below Severe Undervoltage limit with FET bridge
enabled.
• Effect:
Reduced Drive Torque
• Possible Cause:
•
Battery menu parameters are misadjusted
•
Non-controller system drain on battery
•
Battery resisitance too high
•
Battery disconnected while driving
•
Blown B+ fuse or main contactor not closed
4475
POWER MODULE - BDI FAULT
None
4_4
• DriveState = PREVENTED
• LiftUpState = PREVENTED
• Pump BDI Fault
Set:
BDI Percentage charge at 0% when the
pump was activated.
• Effect:
ShutdownPump
• Possible Cause:
•
Battery is fully discharged
•
BDI parameters are mis-tuned
4476
BATTERY VOLTAGE TOO HIGH –
UNPLUG CHARGER
None
4_4
• Enter SafeMode
• LiftDownState = MAX
•
The Ground Module momentarily measured excessively high
battery voltage (VBAT) (>32.0V) and entered SafeMode to
protect system devices. This may be due to improper battery
charging or incorrect voltage batteries being used.
Table 5-13. Diagnostic Trouble Codes (DTC)
DTC
Help Message
Alarm
Flash
Code
Action
Trigger