SECTION 3 - MACHINE CONTROLS, INDICATORS AND OPERATION
3121744
JLG Lift –
3-17
Battery Charge Indicator
(Item 10 )
The battery charge indicator displays the
current charge status of the onboard batter-
ies. RED LED flashing = batteries depleted,
RED LED ON solid = batteries low, RED LED
ON and GREEN LEDs ON = batteries FULL
charge.
System Fault Indicator
(Item 11)
When this indicator light
is flashing a sys-
tem fault has occurred
, possibly stopping
machine operation. Check the MDI indicator
(if equipped)
on the Ground Control Station
to see if a (DTC) Diagnostic Trouble Code(s) is
displayed. An explanation of DTC codes is
shown in Section 5.8.
If the code cannot be cleared by the operator, the machine will
require service by a qualified JLG mechanic.
Alarm
(Item 12)
This alarm mounted on the front of the platform control station
will sound for various machine conditions or warnings such as,
system ready chirp or if the machine tilt warning is activated.
Indoor-Zone A/Outdoor-Zone B Operation Indicator
CE/AUS ONLY (Item 13 - Figure 3-5.)
The Indoor/Zone A (GREEN) indicator and
the Outdoor/Zone B (YELLOW) indicator,
displays which mode the machine is cur-
rently set to operate in.
Indoor-Zone A/Outdoor-Zone B
Operation Mode Switch
CE/AUS ONLY (Item 14 - Figure 3-5.)
This button will toggle between the out-
door/indoor operation modes. Outdoor
mode (Zone B) will restrict platform opera-
tions if operating machine outside rated
wind speed specifications.