SECTION 2 - USER RESPONSIBILITIES, MACHINE PREPARATION, AND INSPECTION
3121261
– JLG Lift –
2-7
SkyGuard Function Test
From the Platform Console:
Test the SkyGuard feature by operating the telescope out func-
tions and then activating the SkyGuard sensor. The telescope out
function will stop and the telescope in function will operate for a
short duration and the horn will sound until the SkyGuard sensor
and footswitch are disengaged.
NOTE:
If the machine is equipped with both SkyGuard and Soft Touch,
functions will not reverse, only stop.
NOTE:
If equipped, ensure the SkyGuard beacon illuminates when Sky-
Guard is activated.
Disengage the SkyGuard sensor, release controls, recycle the foot
switch, make sure normal operation is available.
If SkyGuard remains activated after function reversal or cutout,
depress and hold the SkyGuard Override Switch to allow normal
use of machine functions until the SkyGuard sensor is disen-
gaged.
Summary of Contents for 1500SJ
Page 2: ......
Page 28: ...SECTION 1 SAFETY PRECAUTIONS 1 14 JLG Lift 3121261 NOTES ...
Page 68: ...SECTION 3 MACHINE CONTROLS AND INDICATORS 3 24 JLG Lift 3121261 NOTES ...
Page 100: ...SECTION 4 MACHINE OPERATION 4 32 JLG Lift 3121261 NOTES ...
Page 143: ...SECTION 5 LCD DISPLAY PANEL GENERATION 1 2 3121261 JLG Lift 5 43 Figure 5 29 BCS Lamp Screen ...
Page 149: ...SECTION 5 LCD DISPLAY PANEL GENERATION 1 2 3121261 JLG Lift 5 49 Figure 5 34 Swing DTC Screen ...
Page 166: ...SECTION 6 EMERGENCY PROCEDURES 6 4 JLG Lift 3121261 NOTES ...
Page 180: ...SECTION 7 ACCESSORIES 7 14 JLG Lift 3121261 NOTES ...
Page 208: ...SECTION 8 GENERAL SPECIFICATIONS OPERATOR MAINTENANCE 8 28 JLG Lift 3121261 NOTES ...
Page 212: ......
Page 213: ......