background image

4 JL 

AUDIO 

CleanSweep

®

 CL-SSI

JL AUDIO 

CleanSweep

® 

CL-SSI

 

5

SIGNAL SENSE MODES

The CL-SSI is designed to act as a turn-on and 

turn-off controller for the CL441dsp, which will 
control the turn-on of the rest of the aftermarket 
equipment in the system. There are two modes of 
turn-on operation which can be selected via the 
“SIGNAL SENSE” slide-switch located next to the 
CL-SSI’s power connector. 

Note:

 The “

SIGNAL SENSE

” switch of the 

CL441dsp must be set to “

Off

” when used 

with a CL-SSI.

Signal Sense: ON

With its “

SIGNAL SENSE

” switch in the “

On

” 

position, the CL-SSI will only wake up and turn 
on the CL441dsp when it 12V at its “

IGN

” 

terminal and also senses an input signal from the 
OEM audio source. This mode requires that the 

IGN

” terminal of the CL-SSI be connected to 

a vehicle wire with accessory/ignition-switched 
+12V. (See diagram on page 5.)  

If the vehicle is turned on with the OEM source 

unit turned off, the CL-SSI will remain in Standby 
Mode until the OEM source is turned on and 
playing. The CL-SSI will go into Standby Mode 
(off) approximately one minute after it senses a 
loss of input signal or as soon as the ignition is 
turned off (whichever comes first). 

Signal Sense: OFF

With its “

SIGNAL SENSE

” switch in the “

Off

” 

position, the CL-SSI will wake up and provide 
+12V at its “

REM.OUT

” terminal whenever it 

12V at its “

IGN

” terminal (regardless 

of whether the OEM source is on or not).  This 
position can be useful if another device is being 
used to toggle the CL-SSI on/off, or if the OEM 
system has a conven12 V turn-on output 
(very rare). The “

Off

” position can also be used 

with a manual switch on the wire feeding the 

IGN

” terminal for those who desire manual 

control of on/off functions. This switch should 
be connected to an ignition-sw12V to 
prevent accidental battery drainage. 

POWER  AND TURN-ON CONNECTIONS

Before installing the CL-SSI, disconnect the 

negative (ground) wire from the vehicle’s battery. 
This will prevent accidental damage to the system, 
the vehicle and your body during installation.

The CL-SSI has a 4-pin inline jack located next 

to the “

SIGNAL SENSE

” switch on the signal 

output end of the processor (see diagram on page 
5). This jack accepts the following connections 
through the included color-coded wiring harness 
and plug assembly:

+12 V

”: Co12V

GND

”: Chassis Ground

IGN

”: Sw12V 

REM.OUT

”: Amplifier turn-on (+12V)

Since the CL-SSI does not draw very much 

current during operation, 18 AWG - 16 AWG wire 
is ample for making all of these connections. Use 
good-quality crimp connectors (or solder and 
heatshrink tubing) to join the harness leads to any 
extended wires.  Any wires run through metal 
barriers (such as firewalls), must be protected with 
a high quality rubber grommet to prevent damage 
to the insulation of the wire. Failure to do so may 
result in a dangerous short circuit.

Ideally, the “

+12V

” (constant) and “

GND

” 

(chassis ground) connections should be run to 
the same distribution points that the amplifiers 
and CL441dsp use for their power and ground 
connections. This minimizes the possibility of 
noise in the system.

The “

REM.OUT

” (Remote Output) connection 

provides turn-on voltage to the CL441dsp, which 
in turn will provide turn-on voltage to the rest of 
the aftermarket audio equipment in the system.

The CL-SSI will only turn on when +12V is 

present at its “

IGN

” connection. Conversely, the 

CL-SSI will immediately shut off as soon as +12V 
is removed from this connection. If the OEM 
system does not provide a +12V turn-on lead 
(most do not), we recommend that you connect 
this wire to a 12-volt circuit in the car that is only 
energized with the key in the “Accessory” (ACC) 
or “Ignition” (IGN) positions. This will ensure 
that the audio system will only operate with the 
key in ACC or IGN positions.  If the OEM system 
provides a +12V turn-on lead (rare) you can 
connect this turn-on lead to the “

IGN

” connection. 

CL441dsp POWER

CONNECTION HARNESS

ON OPPOSITE PANEL

SIGNAL SENSE: “OFF”

CL-SSI POWER
CONNECTION HARNESS

CL441dsp

CL-SSI

SIGNAL SENSE: “ON”

SIGNAL

SENSE

Off / On

REM. OUT

IGN

GND

+12V

POWER 

CONNECTOR

Left

Right

Left

Right

FRONT OUTPUTS

REAR OUTPUTS

IGN

GND

+12V

OUTPUTS

POWER

CONNECTOR

LF

RF

LR

RR

SIGNAL SENSE

Off / On

MODE

2-way / 3-way

REM. OUT

POWER AND TURN-ON CONNECTION DIAGRAM

The CL441dsp’s “SIGNAL SENSE” switch must 
be set to “OFF” when used with the CL-SSI. The 
CL-SSI will act as the CL441dsp’s signal-sensing 
turn-on control. The CL441dsp will provide the 
turn-on voltage to the rest of the system, ensuring 
that the equipment will turn on and off in the 
appropriate order, eliminating pops and thumps.

FUSE REQUIREMENTS

The +12V constant wire on the CL-SSI power 

harness has an inline 1 amp, fast blow AGC (small 
glass-bodied) fuse for protection of the unit. Do 
not remove this fuse or replace it with a different 
value of fuse.

Summary of Contents for CleanSweep CL_SSI

Page 1: ...and installation equipment to ensure optimum performance from this product without compromising your vehicle s functionality Due to the complexity of modern vehicle systems we do not recommend self installation unless you have extensive experience in automotive electrical systems If you have any questions regarding the instructions in this manual or any aspect of the product s operation please con...

Page 2: ...time to read this manual and that you plan out your installation carefully The CL SSI should be mounted as close to the CL441dsp as possible The harness supplied for connecting the CL SSI s outputs to the inputs of the CL441dsp is 3 feet 91 cm long Safety Considerations Your CleanSweep CL SSI needs to be installed in a dry environment and in a manner which does not interfere with your vehicle s sa...

Page 3: ... Constant 12V GND Chassis Ground IGN Switched 12V REM OUT Amplifier turn on 12V Since the CL SSI does not draw very much current during operation 18 AWG 16 AWG wire is ample for making all of these connections Use good quality crimp connectors or solder and heatshrink tubing to join the harness leads to any extended wires Any wires run through metal barriers such as firewalls must be protected wit...

Page 4: ... easy to damage expensive vehicle systems in modern automobiles Never assume that you have found appropriate wires without consulting a reliable wiring diagram or without performing signal testing with safe test equipment If you are not comfortable with reading wire diagrams or testing signals please enlist the services of your authorized JL Audio dealer to perform the installation It is vital to ...

Page 5: ...one end of the unit 2 Way Mode In this mode the CL SSI will sum an OEM subwoofer or woofer signal to front and rear signals that have been high pass filtered creating front and rear full range output channels while retaining the functionality of the OEM front to rear fader control PX 1BTT XPPGFS JHI 1BTT NJE UXFFUFS Z K Z Z i 165 w SFBS 03 i 165 w GSPOU K Z i 165 w To use the CL SSI in this mode 1...

Page 6: ...res the use of the CleanSweep Calibration CD included with the CL441dsp The CL SSI s level indicators have no significance with any other test signal or with music program material SPECIFICATIONS CleanSweep CL SSI Signal Summing Interface Electrical Specifications Power Supply Type PWM Switching Supply Regulated Operating Voltage 9 16V DC Standby Mode Current Draw 2 mA Operating Current Draw 0 5 A...

Page 7: ... with the date of the original purchase at retail and no warranties whether express or implied shall apply to this product thereafter Some states do not allow limitations on implied warranties therefore these exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state If you need service on your JL AUDIO product Al...

Reviews: