PAGE 45 of 140
DP0029 Rev 02.2
The etched line
(Fig. 81)
near the base
of the swivel mount can be used
to align the front swivel mount to a
horizontal position.
NOTE:
The front mount must be
horizontal when using the
pivoting probe holder frame to
scan longitudinally on piping.
5.6.2. Umbilical
To mount the umbilical to the crawler, follow these steps
1.
Align the pins of the umbilical to the connector at the rear of the
SKOOT HT
(Fig. 82)
.
2.
Twist the umbilical’s sleeve clockwise locking the umbilical in place
(Fig. 83)
.
Fig. 81 - Return mount to horizontal position
WARNING!
FALLING OBJECT HAZARD
.
or operating at heights greater than 2 m
(6 ft)
, ensure
the umbilical strain relief never points upwards as
shown in
(Fig. 85)
. The crawler could fall.
SEVERE
INJURY
or
DEATH
could result.
Fig. 82 - Connect to umbilical
Fig. 83 - Align with crawler’s umbilical mount