Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 –
www.jide.be
-
[email protected]
CARINO (EN) February 2020
44
PRODUCT FICHE – EU 2015/1186
Page 1: ...USE AND MAINTENANCE CARINO 67 CARINO 77 Congratulations You have chosen an appliance of the Jid range and we would like to thank you for it We are convinced that it will bring you warmth and comfort I...
Page 2: ...etup of the remote control with the insert 9 4 Starting the device 10 5 Turning off the device 11 6 Setting of the pace 11 7 Security or automatic stop 14 8 Convection ventilation 14 9 Maintenance 14...
Page 3: ...s well as smoke flues The appliance may not be modified as it could present a real danger and will invalidate the warranty A list of our dealers installers is available on our site www jide be en Befo...
Page 4: ...ating problem It is strictly forbidden to use other decorations than the ones supplied with the device under penalty of dysfunction of the insert and cancellation of the warranty It is strictly forbid...
Page 5: ...sted in factory according to technical specifications written on the descriptive plates below Every insert has a proper descriptive plate mentioning the serial number of the device and the type of gas...
Page 6: ...Jid s a Rue des Meuneries 11 B 4650 HERVE Belgique T l 32 87 31 75 12 Fax 32 87 31 75 11 www jide be info jide be CARINO EN February 2020 6...
Page 7: ...to get the desired temperature If the remote is too close of the device it will start pilot mode too quickly if the remote is too far it will react too late The insert also has a convection air ventil...
Page 8: ...ush on high flame button to settle hours and on low flame button to settle minutes Then push on start stop button or wait until the display stops blinking 2 2 Pattern for set point temperatures To use...
Page 9: ...ure push four times on SET button of the remote control when it is in MAN mode or twice when it is in TEMP mode TEMP mode and appear on display Push at length on SET button until temperature flashes o...
Page 10: ...his manual Check the manual button of the valve is on position ON On the remote control push simultaneously on start stop and high flame button A beep comes from the receptor 1 Push on RESET button on...
Page 11: ...Turning off the device Push on start stop button on the remote control You hear a beep from the receptor The burners and the pilot are turned off 6 Setting of the pace 6 1 Manual mode When the starti...
Page 12: ...isplay 6 2 Thermostatic mode In this working mode the remote control acts as the thermostat According to the room temperature detected it handles automatically the working of the insert to reach the s...
Page 13: ...ping mode go to point 6 1 To set the operating ranges push 5 times on SET button of the remote control TIMER mode and P1 or P2 appear on display Push then on SET button until the clock blinks and appe...
Page 14: ...matically by a thermal switch airstat The speed setting is done by the speed controller supplied with the device Attention The device can NOT work without ventilation It is necessary to cool down the...
Page 15: ...the door is self supporting on the top of the heating chamber Nevertheless remove the screws carefully because the airtight seal can have a spring effect Once the screws are removed raise the door by...
Page 16: ...e the 6 screws in the threads before tightening in order to avoid to pressurise the seal and to have difficulty placing the next screws 9 2 Annual maintenance For a good working of the device and for...
Page 17: ...tions than the one supplied with the device under penalty of dysfunction of the insert and cancellation of the warranty It is strictly forbidden to introduce foreign object inside the device The appli...
Page 18: ...de Veerseweg 23 4332 SH Middelburg The Netherlands and JEREMIAS connections by Detandt Simon Rue d Herchies 37 7011 Ghlin Belgium Chimney settings authorised are only those mentioned in this manual Re...
Page 19: ...cessible Clean the pipe previously traces of filings before connecting to the fireplace This connection is done with a flexible of minimum 500 mm length in order to allow the electronic drawer to go o...
Page 20: ...bruary 2020 20 Chimney setting 1 Wall outlet type C11 1 1 Minimal setting 1 2 Maximal setting Attention only authorised for G20 and G25 Note Remove the baffle for this setting A B C D A Elbow 45 B G20...
Page 21: ...first elbow 45 at the end of the fireplace in this formula B E 1 D F y x C 20m y number of elbow 4 max C 1 or 0 5 according to the type of elbow C E F G A B C A Elbow 45 B 2 m min length 20 m max C En...
Page 22: ...o place the restriction remove the baffle remove the two screws on the chimney connection and fix the restriction with these two screws Replace the baffle 2 2 Complexe setting A B C D C E F A Elbow 45...
Page 23: ...must be swept and cleaned before connecting it to the insert The pipe connection must be completely sealed on its basis and outlet on the roof To proceed use renovation kit ONTOP USSAN or JEREMIAS TW...
Page 24: ...ide be info jide be CARINO EN February 2020 24 A B C D E F A Elbow 45 B Concentric length if necessary C Base renovation kit USSAN D Flexible length dia 100 20 m max E High piece renovation kit USSAN...
Page 25: ...jide be info jide be CARINO EN February 2020 25 Placing of the outlet pipes The position of pipes connected to the insert terminals must respect local standards in force More often than not NBN51003...
Page 26: ...elf supporting on the top of the heating chamber Nevertheless remove the screws carefully because the airtight seal can have a spring effect Once the screws are removed raise the door by placing one h...
Page 27: ...11 www jide be info jide be CARINO EN February 2020 27 Output of gas drawer Connection of gas supply Electric connection Note if it is foreseen to connect warm convection air ducts according to the a...
Page 28: ...N February 2020 28 1 Remove the disk 2 Fix the duct with self boring screws Remove the chimney connection then fit the device in the housing avoiding any damaging of the electric cable of the ventilat...
Page 29: ...components Gas sealing Sealing must be checked for the complete circuit of gas income to the valve by a certified installer or certified control organism A test with a leak detector or soap water mus...
Page 30: ...heck the manual button of the valve is on position ON Push simultaneously on start stop button and high flame button on the remote control A beep sounds from the receptor A sequence of beeps 1 per sec...
Page 31: ...cted in order to avoid problems of working or of lighting It is strictly forbidden to use or to add decorating elements which do not belong to the kit supplied with the fireplace otherwise the warrant...
Page 32: ...HERVE Belgique T l 32 87 31 75 12 Fax 32 87 31 75 11 www jide be info jide be CARINO EN February 2020 32 Fitting log 1 Fitting log 2 ATTENTION Different location according to the type of gas G20 G25...
Page 33: ...itting of the finishing frame option The fireplace must be aligned to the masonry wall to attach the frame in a right way Originally the frame is a 3 sided frame A 4 sided frame is available in option...
Page 34: ...g Wrong fitting Interventions on components ATTENTION Before every intervention on the device close the gas income on the bloc valve and remote the electric supply of the ventilation Valve and electro...
Page 35: ...ull gently on the box to separate the Velcro pads To replace control cables proceed so Pilot The thermocouple of the pilot is removable without opening the insert By removing the gas components drawer...
Page 36: ...evious point Remove then the two burners raise the right side of the burner 1 to get it out of the centring dowels then slide to the right until the venture gets out of the injector 2 ATTENTION when y...
Page 37: ...do not have the same diameter Respect their location There is a marking on both of them Front burner G20 G25 170 1 7 mm Back burner G20 G25 130 1 3 mm Remove the two nuts placed inside the fireplace a...
Page 38: ...e accessible by the two hatches located on the back side of the heating chamber Remove the 8 screws of each hatch to remove the hatches Fans and airstat placed on the left are now accessible To clean...
Page 39: ...uum cleaner Insist on burners trays the burners contour plate the back of the heating chamber the air inlet tray where the injectors are and the location of the pilot During this intervention act care...
Page 40: ...inside of the chimney s pipe and to ensure there is no obstruction Check the states of the different seals and replace them if necessary Check the state of the door glass If it is damaged it must abso...
Page 41: ...osition Check piezo wiring Replace the pilot Lighting of the pilot but no of the burners Pilot Check the intensity of the flame Check if obstruction of the pilot Check thermocouple Check gas pressure...
Page 42: ...the insert cool down Check convection of the device ventilation aeration Check chimney s draft Wait for return to normal Thermostatic function does not react Communication Batteries Components Check...
Page 43: ...Jid s a Rue des Meuneries 11 B 4650 HERVE Belgique T l 32 87 31 75 12 Fax 32 87 31 75 11 www jide be info jide be CARINO EN February 2020 43 Architect plans CARINO 67 CARINO 77...
Page 44: ...Jid s a Rue des Meuneries 11 B 4650 HERVE Belgique T l 32 87 31 75 12 Fax 32 87 31 75 11 www jide be info jide be CARINO EN February 2020 44 PRODUCT FICHE EU 2015 1186...
Page 45: ...vermiculite The joints of the door and of the various hatches The window liable to undergo shocks or rough handling Normal wear and tear and lack of maintenance Damage resulting from an installation...
Page 46: ...87 31 75 12 Fax 32 87 31 75 11 www jide be info jide be CARINO EN February 2020 46 Warranty card Model JIDE CARINO 67 77 Purchaser Name First name Address Postcode City Country Seller s stamp Stick yo...
Page 47: ...Jid s a Rue des Meuneries 11 B 4650 HERVE Belgique T l 32 87 31 75 12 Fax 32 87 31 75 11 www jide be info jide be CARINO EN February 2020 47 NOTES...
Page 48: ......