INSTALLATION,
continued
6
JH INDUSTIRES INC.
(WIDTH) + 2”
(LENGTH) + 2”
PIT DRAIN
3”X3”X1/4’ MIN. CURB
ANGLE WITH ANCHOR
STRAPS (BY OTHERS)
ELECTRICAL POWER
SUPPLY LOCATION TO BE
DETERMINED BY CUSTOMER
POWER PACK
20”
2-1/2” MIN. CONDUIT
WITH 14” MIN. RADIUS
20”
DEPTH = LOWERED 1/2”
PIT FLOOR MUST BE LEVEL
SUPPLIED BY OTHERS
FIGURE #6
—Three Sided Pit Diagram
FIGURE #7
—Standard Pit Diagram
(BRIDGE WIDTH) + 2”
(PLATFORM LENGTH) + 6-1/2”
7”
8” DIA. BUMPER POST
(2) REQUIRED (BY
OTHERS)
3”X3”X1/4’ MIN. CURB
ANGLE WITH ANCHOR
STRAPS (BY OTHERS)
60”
60”
20”
20”
2-1/2” MIN. CONDUIT
WITH 14” MIN. RADIUS
DEPTH = LOWERED 1/2”
POWER PACK
1/2” DEEP
BRIDGE RECESS
(BRIDGE
LENGTH) - 3-1/2”