KI-OM-0591 Rev 3
A.5
F43
ES3
Event 3 type
0
Type of input used to trigger
this event
Eho3
Event 3 hold action
0
EIL3
Event 3 interlock
0
EH3
Event 3 differential gap
2
Prevents chattering of event
output
EVT3
Event 3 delay timer
0
Delay of action of event after
trigger
EEo3
Event 3 action at input error
0000
F44
ES4
Event 4 type
0
Type of input used to trigger
this event
Eho4
Event 4 hold action
0
EIL4
Event 4 interlock
0
EH4
Event 4 differential gap
2
Prevents chattering of event
output
EVT4
Event 4 delay timer
0
Delay of action of event after
trigger
EEo4
Event 4 action at input error
0000
F45
CTr1
CT1 ratio
800
CTA1
CT1 assignment
1
HbS1
Heater break alarm 1 (HBA1) type
1
HbC1
Number of heater break alarm 1 (HBA
1) delay times
5
F46
CTr2
CT2 ratio
800
CTA2
CT2 assignment
0
HbS2
Heater break alarm 2 (HBA2) type
0
HbC2
Number of heater break alarm 2
(HBA2) delay times
5
F50
Pd
Hot/Cold start
0
Hot start 1
PdA
Start determination point
3
CAM
External input type
0
MCH
Master channel selection
0
TrK
SV tracking
1
Used
MVTS
MV Transfer function
0
PVTS
PV Transfer function
0
Unused
Table 3
Engineering Mode (Continued)
Temperature
Controller
Engineering Mode
Function
Block
Parameter
Spec.
Value
Description
Code
Description
Summary of Contents for WHE - 3
Page 2: ......
Page 6: ...vi KI OM 0591 Rev 3 Intentionally blank ...
Page 8: ...viii KI OM 0591 Rev 3 Intentionally blank ...
Page 46: ...38 KI OM 0591 Rev 3 Part Identification Intentionally blank ...
Page 56: ...B 2 KI OM 0591 Rev 3 Intentionally blank ...
Page 61: ...KI OM 0591 Rev 3 C 5 Sheet 2 of 2 ...
Page 62: ...C 6 KI OM 0591 Rev 3 WHE 3 Electrical Schematic 440 V Heater Circuit With Remote ...
Page 63: ...KI OM 0591 Rev 3 C 7 WHE 3 Electrical Schematic With Remote Busbar Manufacturing Detail ...
Page 65: ...KI OM 0591 Rev 3 C 9 Sheet 2 of 2 ...