A.4
KI-OM-0591 Rev 3
F30
LoGC
Output assignment
1
oTT1
Timer 1
0.0
oTT2
Timer 2
0.0
oTT3
Timer 3
0.0
oTT4
Timer 4
0.0
EXC
Energized/De-energized
0011
Status of DO 1-4
ALC1
Alarm (ALM) lamp lighting condition 1 0001
Lamp status of EV1-4
ALC2
Alarm (ALM) lamp lighting condition 2 0000
Lamp status of HBA1 & 2
ss
Output status at STOP mode
0010
F33
Ao
Transmission output type
1
Selection of output to display
(PV, MV, etc.)
AHS
Transmission output scale high
100.0
High limit of output to display
ALS
Transmission output scale low
0.0
Low limit of output to display
F41
ES1
Event 1 type
0
MV1 High (Heat Side)
Eho1
Event 1 hold action
0
Off
EIL1
Event 1 interlock
0
Unused
EH1
Event 1 differential gap
2
Prevents chattering of event
output
EVT
Event 1 delay timer
0
Delay of action of event after
trigger
EEo1
Event 1 action at input error
0000
F42
ES2
Event 2 type
0
MV1 High (Cool Side)
Eho2
Event 2 hold action
0
Off
EIL2
Event 2 interlock
0
Unused
EH2
Event 2 differential gap
2
Prevents chattering of event
output
EVT2
Event 2 delay timer
0
Delay of action of event after
trigger
EEo2
Event 2 action at input error
0000
Table 3
Engineering Mode (Continued)
Temperature
Controller
Engineering Mode
Function
Block
Parameter
Spec.
Value
Description
Code
Description
Summary of Contents for WHE - 3
Page 2: ......
Page 6: ...vi KI OM 0591 Rev 3 Intentionally blank ...
Page 8: ...viii KI OM 0591 Rev 3 Intentionally blank ...
Page 46: ...38 KI OM 0591 Rev 3 Part Identification Intentionally blank ...
Page 56: ...B 2 KI OM 0591 Rev 3 Intentionally blank ...
Page 61: ...KI OM 0591 Rev 3 C 5 Sheet 2 of 2 ...
Page 62: ...C 6 KI OM 0591 Rev 3 WHE 3 Electrical Schematic 440 V Heater Circuit With Remote ...
Page 63: ...KI OM 0591 Rev 3 C 7 WHE 3 Electrical Schematic With Remote Busbar Manufacturing Detail ...
Page 65: ...KI OM 0591 Rev 3 C 9 Sheet 2 of 2 ...