JetMove 203-230
9.1 Error Messages
Jetter AG
65
9
Diagnostics
9.1
Error Messages
Note!
In the case of an error message, the letter "F" and two successive numbers
appear on the 7-segment display every second.
Error Message Table JetMove 203-230
Error
Number
Type of Error
Description
Effect
Error Correction
F 00
Hardware error
Internal hardware
defect
– Immediate
pulse disable
– Cut drive controller
from power lines
– Return the amplifier
for repair
F 01
Internal voltage
supply error
One or more power
supply voltages are
beyond their limits
– Immediate
pulse disable
– Cut drive controller
from power lines
– Return the amplifier
for repair
F 02
One mains phase
has failed
(is only active in
case of a 3-phase
connection)
Failure of one of the
mains phases
– Immediate
pulse disable
– Check fuses and
wiring
– Acknowledge failure
F 03
Motor cable fault
The motor cable is
broken
Please note: The
motor cable is tested
when the drive
controller is enabled
for the first time
– Immediate
pulse disable
– Check the motor
cable connections
– Acknowledge failure
F 04
DC link
overvoltage
A DC link voltage
of> 480 V has been
detected
– Immediate
pulse disable
– Check input voltage
supply
– If the motor is used as
a generator, reduce
the regenerating
power
– Acknowledge failure
Summary of Contents for JetWeb JetMove 203-230
Page 34: ...4 Physical Dimensions JetWeb 34 Jetter AG...
Page 42: ...5 Technical Data JetWeb 42 Jetter AG...
Page 62: ...7 Description of Connections JetWeb 62 Jetter AG...
Page 70: ...9 Diagnostics JetWeb 70 Jetter AG...
Page 76: ...10 Wiring Diagrams JetWeb 76 Jetter AG...
Page 79: ...JetMove 203 230 Appendix Jetter AG 79 Appendices...
Page 80: ...Appendices JetWeb 80 Jetter AG...