JetMove 203-230
7.5 Digital Inputs, Logic Power Supply
Jetter AG
59
*) is connected to the ground of the control system.
Common
ground
Ground
*)
for all
inputs and supply of
the logic
Common
ground
Ground
*)
for all
inputs and supply of
the logic
DC 24 V
Voltage
supply of
processor
logics
DC 20 .. 30 V
(I < 0.6 A)
BRAKE 1
Braking relay
contact Br1
Relay contact for motor
holding brake
The relay can be operated
either by the control
program or by the firmware
of the JetMove 203-230 at
release of the motor
current.
A free-wheeling diode is
necessary if not integrated
in the motor already.
V
max
= DC 30 V
I
max
= DC 2 A
Type NO
These connections
are only for devices
having got the same
reference to ground
as the power supply
of the logic.
BRAKE 2
Braking relay
contact Br2
⊥
⊥