JetMove 203-230
7.6 Jetter System Bus
Jetter AG
61
Permissible Cable Lengths
Baud rate
Max. cable
length
Max. stub line
length
Max. overall stub
line length
1 MBaud
30 m
0.3 m
3 m
500 kBaud
100 m
1 m
39 m
250 kBaud
200 m
3 m
78 m
125 kBaud
200 m
-
-
System Bus Cable of Cable Confection # 530
Shielding
BUS-OUT
Connect shield with the greatest
possible surface area!
Metallized enclosure necessary!
BUS-IN
Pin
Signal
Pin
1
CMODE0
1
2
CL
2
3
GND
3
4
CMODE1
4
5
TERM
5
6
Vacant
6
7
CH
7
8
Vacant
8
9
Do not connect
9
Shield
Shield