5 Technical Data
JetWeb
36
Jetter AG
Cross-sectional area of supply-
cable conductors
Min. 0.75 mm
2
Cross-sectional area of motor
supply cable
Min. 0.75 mm
2
, 50 m length max.
(if you need greater lengths, please contact
Jetter AG)
Line filter
Line filter ensuring unrestricted EMC
in a
residential environment to DIN EN 61800-3.
The following filters can be applied with
input circuits:
– NEFB 10332 with I
r
= 16 A
– NEFB 10333 with I
r
= 25 A
– NEFB 10334 with I
r
= 36 A
Voltage supply of processor logics
(demands on power supply
module)
• 24 V DC (20 .. 30 V)
•
≤
0.6 A
• The voltage output of the power supply
unit must comply with the SELV or PELV
type.
Internal ballast resistor
• Resistor: 200
• Continuous power: 100 W
• Maximum capacity: internally limited to
1 kW at 0.6 s (warning and error
message)
Residual voltage
To avoid hazard of electrical shock wait at
least 5 minute after switching-off the digital
servo amplifier before attempting to pull out
the plug or remove this unit (refer to
page 17).
Leakage current
> 3.5 mA
See "DANGER resulting from electric
shock!" on page 38.
Enable (E),
Reference switch (R);
Limit switch RH (L+), and
limit switch LH (L+);
Input (Inp)
• DC 20 V ... 30 V related to the controller
potential
• 7.5 mA max. input current per input
• See chapter 7.5 "Digital Inputs, Logic
Electrical Specification
Ω
Summary of Contents for JetWeb JetMove 203-230
Page 34: ...4 Physical Dimensions JetWeb 34 Jetter AG...
Page 42: ...5 Technical Data JetWeb 42 Jetter AG...
Page 62: ...7 Description of Connections JetWeb 62 Jetter AG...
Page 70: ...9 Diagnostics JetWeb 70 Jetter AG...
Page 76: ...10 Wiring Diagrams JetWeb 76 Jetter AG...
Page 79: ...JetMove 203 230 Appendix Jetter AG 79 Appendices...
Page 80: ...Appendices JetWeb 80 Jetter AG...