background image

16

GB

Preface

Your unit has been built in accordance with the latest state of the art, and is safe. However, the unit can be
dangerous if it is operated by persons who have not received the necessary training or instruction, or if it is used
improperly. Therefore, everyone entrusted with the task of installing the unit, setting it into operation, operating,
maintaining and repairing it, must read and understand the Operating Instructions and - especially - the Safety
Instructions. Before using the unit for the first time, you and/or your personnel should definitely receive instruc-
tions from the specialist consultant. If, contrary to expectations, technical defects occur in your unit, please
contact the customer service department or your dealer.

LIST OF CONTENTS

PAGE

1

SAFETY INSTRUCTIONS ......................................................................................................................

16-17

2

INSTALLING THE WALL NICHE IN CONCRETE SHUTTERED POOLS .............................................. 18-19

3

FINAL ASSEMBLY INSTRUCIONS ........................................................................................................ 20-21

4

OPERATION / INFORMATION FOR THE USER OF THE UNIT .............................................................

23-27

4.1

BEFORE STARTING ............................................................................................................................

22

4.2

FIRST TIME OPERATION ....................................................................................................................

22

4.3

STARTING THE UNIT ..........................................................................................................................

23

4.4

STRENGTH OF THE JET ....................................................................................................................

23

4.5

MASSAGE .......................................................................................................................................

23-24

4.6

SWIMMING 

AGAINST THE CURRENT ................................................................................................ 24

4.8

WINTERIZATION .................................................................................................................................

24

4.8

AGAIN OPERATION ............................................................................................................................

24

5

SERVICE ...................................................................................................................................................... 24

6

FITTING INSTRUCTION FOR HANDGRIPS ............................................................................................... 25

7

INFORMATION FOR THE ELECTRICIAN .............................................................................................. 26 -27

1

SAFETY INSTRUCTIONS

1.1 Before Setting into Operation

Before installation and setting into operation, the Safety Instructions and the Operating Instructions
must be carefully read and observed. You must definitely comply with the requirements of the uwe
company and of the standards authorities.

1.2 Setting the Unit into Operation for the First Time

Before the unit is set into operation, the local safety regulations and the Safety Instructions must always be complied
with.

1.3 Sources of Danger

Warning!
The JETSTREAM system forces up to 700 litres of water per minute into the pool through the nozzle. If all of
this enormous force is used for massage, it can cause injuries to muscles and to connective tissue, as well as
internal injuries. Because of the reduced electrical resistance of the human body in swimming pools and the
resulting increased probability of the occurrence of dangerous currents in the body, increased safety requirements
are imposed on the electrical installation.

Summary of Contents for EUROJET

Page 1: ...1 INSTALLATION AND OPERATING INSTRUCTIONS EuroJet Eurojet Swimjet Instructions www agbudget co uk Luxury Swimming Pool Equipment at Budget Prices...

Page 2: ...NIT 23 4 4 STRENGTH OF THE JET 23 4 5 MASSAGE 23 24 4 6 SWIMMING AGAINST THE CURRENT 24 4 8 WINTERIZATION 24 4 8 AGAIN OPERATION 24 5 SERVICE 24 6 FITTING INSTRUCTION FOR HANDGRIPS 25 7 INFORMATION FO...

Page 3: ...nt is dry and that the motor is protected by a suitably sized floor drain to prevent flooding The control panel should be installed either in a dry walkway or in an adjacent room if possible higher th...

Page 4: ...by placing in protective conduit or through adjacent cable ventilation ducts Tile plan fig 2 Render and tile to inner edge of wall niche Pools with plastic liner fig 3 Proceed as shown in fig 3 shutt...

Page 5: ...mping frame air inlet tube for air suction end part to be installed 5 10 cm above water level pool wall sunk screw M 8 x 35 use clamping frame for cutting and drilling label top gasket concrete max wa...

Page 6: ...fitted to the pool wall beforehand with concrete wall fixings The pump should be secured with anti vibration mountings Alternatively the pump should be secured with appropriate fixings on a concrete...

Page 7: ...nce with EN 60335 2 41 Connection to the power supply is effected by means of a 5 x 2 5 mm 3N PE 400V cable or a 4 x 2 5 mm 3 PE 230 V cable Both a power switch with which the unit can be isolated fro...

Page 8: ...irements must be met and safety precautions must be observed Before operating the unit for the first time rotate the pump by hand several times at the ventillating fan in the direction shown Do not se...

Page 9: ...d detach the massage fitting switch off the pump For point massage hold the nozzle of the massage hose firmly in your hand under water Guide the nozzle of the massage hose over the required places but...

Page 10: ...the surface is made to flow strongly without excessive effervescence being visible on the water surface 4 7 Winterization If the unit is installed in a pool where there is a danger of frost the water...

Page 11: ...rete shuttered pools Fitting in steel aluminium or polyester pools 800 58 105 45 ca 736 JETSTREAM 45 58 7 36 8 50 nozzle hand grips are identical and can be interchanged broken screw are only needed f...

Page 12: ...kers Pay attention to cable length and voltage drop For 230 V 16 A slow blow fuses or 16 A automatic circuit breakers Pay attention to cable length and voltage drop 4 Power consumption The maximum pow...

Page 13: ...F2 S1 5 3 1 4 2 6 5 3 1 13 F3 1 2 F4 RD RD K2 A1 K2 2 1 3 A1 1 2 5 4x2 5mm K1 PE M1 3 M K1 3 5 4 2 14 6 2 60 min A2 A2 A1 N 1 18 S2 2 3 2 4 3 3 6 3 3 14 3 3 15 1 3 5 13 18 3 5 PE PE L1 L2 L3 N PE L1 L...