Pre-Installation

Standards and Regulations

To install a Jets™ product, it is first required that the room be prepared according to all local, state and federal standards and requirements. 
Industry specific standards must also be met. Considerations that must be made include but are not limited to:

● Appropriate dimensioned drain pipes.
● Water barrier or membrane.

Installations required to meet AS/NZS 3500 series of Standards must adhere to the following: 
(Ref: Australian and New Zealand Standards: AS/NZS 3500  - AS3500 Part 2 Sanitary Plumbing and Drainage )

● Discharge by a vacuum toilet system shall be regarded as "pumped discharge" and shall be pumped according to AS/NZ3500 "Pumped 

Discharge" requirements.

● Installation of the vacuum toilet system shall be according to the requirements of AS/NZ 3500.2 Sanitary Plumbing and Drainage.

Tools and Training

No special tools other than those used in standard plumbing installations are required. No special training is required to install this product. 

Water Barrier

Note that in some countries, and as per the majority of standards and regulations, it is prohibited to mount toilets directly onto the wall if mounting 
requires that the water barrier be compromised. Check requirements according to local codes and standards before beginning any installation 
work.

Pre-Installation Considerations

It is recommended that items such as wall mounted release buttons, drainage and piping etc. is installed prior to installation of the toilet.

Suitable floor material for screw mounting must be used.  When installing the toilet, a water level is to be used to ensure a horizontal surface on 
the bowl.

Connection with Mains Water

The toilet valve connection required is a 1/2" BSP standard connection. The water pressure must be a minimum of 2 bar and must not exceed 7 
bar. 

Connection without Mains Water

The toilet valve may be connected to a local water supply such as a container, tank or can. A water pump must be used. Refer to the individual 
product data sheet for further instructions regarding connections.

Backflow Prevention

Backflow Prevention 
Please refer to local, state, federal and/or international regulations regarding the extent of backflow requirements for your specific installation.

For installations whereby the valve is to be connected to a drinking water supply, it is recommended that the water connection is installed with a 
backflow prevention device.  Please refer to the local regulations in your area.  If backflow prevention is required in Australia, refer to AS/NZ3500.1 
Backflow Prevention.

Toilet Seat Cover

Note:  Be aware that the toilet seat cover (when opened) may not rest on the back wall if the toilet is mounted away from the wall.  Care should be 
taken not to force the lid open beyond it's natural limitations.

Summary of Contents for TO650PO

Page 1: ...roduced in any form Jets Vacuumarator Helivac VC VOD CVS and Softsound are trademarks and or registered trademarks of Jets Jets AS All rights reserved Technical Data Outside Dimensions 550 x 385 x 475...

Page 2: ...t 7 Valve See selected product 8 Release Button See selected product Component s avaliable as replacement parts Accessories Construction Characteristics Vacuum Breaker Kit 034507320 Rubber Elbow 50 w...

Page 3: ...From the finished surface 110mm L 70mm M 195mm N 170mm O 150mm P 172mm Q 410mm R 235mm B 1 B 2 B 3 B 2 1 B 3 1 Pipe Connection Dimensions All measurements given are based on use of a Jets rubber elbow...

Page 4: ...ified lifting points or as instructed in the current IOM Note Lifting devices eyebolts slings spreaders etc must be rated selected and used for the entire load being lifted 1 4 Caution Safety equipmen...

Page 5: ...local codes and standards before beginning any installation work Pre Installation Considerations It is recommended that items such as wall mounted release buttons drainage and piping etc is installed...

Page 6: ...or more specific technical details refer to the individual data sheet For further information on any of the instructions supplied any questions regarding installation or the products please contact yo...

Page 7: ...y of technical information regarding freezing protection measures 5 CAUTION Never use automotive antifreeze ethylene glycol in the toilet system 6 Turn off the power NOTE Failure to adequately protect...

Page 8: ...equipment and take measures to prevent future damage to the system Note that frost or freezing may damage sanitary systems if precautions have not been taken Contact your nearest Jets supplier for inf...

Page 9: ...kflow in the installation Check the pipes have been correctly installed The Non return Valve on the discharge line if installed is malfunctioning Clean the Non return Valve If connected to a tank the...

Reviews: