PROBLEM:
Jets are weaker than normal or do not work at all, but in both cases the pump is running.
Cause: 1.
Jet handle(s) is partially or fully closed.
Solution:
Open jet handle(s).
Cause: 2.
Spa filter cartridge is dirty.
Solution:
See "Cleaning Your Filter" in this Owner's Manual.
Cause: 3.
There is air trapped in the spa equipment or its face piping.
Solution:
Open the air-bleed valve on each pump housing and allow air to bleed out of system. Be sure to
tighten each air-bleed valve as soon as water starts to flow out.
Cause: 4.
The Suction Fitting(s) are blocked.
Solution:
Remove any item or debris that is blocking each Suction Fitting.
Cause: 5.
The JetZone Divider is not installed (This only applies to spas that have two pumps).
Solution:
Re-install in the appropriate JetPak position. (Warning: Running your spa without a JetZone Divider
can cause serious damage to your pump.)
Cause: 6.
Slice Valve is closed.
Solution:
Open Valve and secure with Valve Keeper.