Cut out point for ceiling penetration

Using the installation manual for the fireplace being installed, position the fireplace into the desired
location ensuring that all clearances stipulated by the fireplace manufacture are achieved. Once in
position, check using a laser or plum bob the location of the flue penetration in the roof cavity. The
flue will need to pass through a section of ceiling which can house the main flue bracing bracket.
Ideally this is between two roof trusses which can be used to mount the flue bracing bracket. (See
FIG 2) If this cannot be achieved, additional frame work in the roof will be required to house the flue
bracing bracket. Please ensure clearances are met when fi�ing the flue bracing bracket and
constructing any additional frame work. If the roof cavity is used as usable living or storage space or
has blown in insulation, an a�ic shield is recommended to ensure the 50mm clearance to the Safety
Vent AIR pipe.

FIG 2

Fitment of VisionLINE Safety Vent AIR pipe

Once the flue bracing bracket is in place, fit a section of VisionLINE AIR pipe in place ensuring that
enough pipe has passed down through the ceiling to meet the clearance requirements before using
the conversion piece to convert to VL double wall stove pipe (see FIG 3)

FIG 3.

Air flue
support 1

PAGE 3

150mm min

Summary of Contents for VisionLINE AIR

Page 1: ...Safety Vent AIR Instruc on Manual...

Page 2: ...sis ng of flues in 150 mm of 0 6 mm 316L stainless steel insulated with 25 mm Morgan Frax ceramic insula on with a density of 128 kg m air gap of 20 mm 20 mm Morgan Frax ceramic insula on 128 kg m and...

Page 3: ...ystems and Flue System Clearances In Australia and New Zealand this flue system can ONLY be used for solid fuel systems Wood Preparation Before installation planning is essential for an efficient safe...

Page 4: ...cannot be achieved additional frame work in the roof will be required to house the flue bracing bracket Please ensure clearances are met when fi ing the flue bracing bracket and constructing any addit...

Page 5: ...he locked position VisionLINE safety vent AIR CANNOT be cut if you require smaller sections please contact your distributor Roof Penetration Once the safety vent AIR flue has passed though the roof th...

Page 6: ...the flue system is compatible with direct spigot air intake If the fireplace uses a rear or floor entry intake system a T piece section can be used Part number VF 3 60 090 as the final VL stove pipe s...

Page 7: ...eight requirements per AS NZS 2919 Elbow support bracket kit VF 3 60 246 Use of bends 45o Bends can be used on this flue system Either the stove pipe flue or the VisionLINE safety vent flue can be off...

Page 8: ...UPPORT 2 8 VF 3 60 002 AIR FLUE SUPPORT 1 9 VF 3 60 108 AIR FLUE STOVE PIPE TO SAFETY VENT TRANSITION 10 VF 3 60 105 AIR FLUE STOVE PIPE 620 1080MM ADJUSTABLE 11 VF 3 60 104 AIR FLUE STOVE PIPE 420 61...

Page 9: ...D 65 mm E 193 mm 148 5 Ceiling Ring VF 3 60 110 Flush spigot adapter 193 L 30 Adjustable Stove pipe 193 L 30 Stove pipe Part number Joined length Total length VF 3 60 100 220mm 250mm VF 3 60 106 970mm...

Reviews: