Standard flue components

#

Code

Description

1

VF-3-60-001

AIR FLUE RAIN CAP

2

VF-3-60-203

AIR FLUE SAFETY VENT 1000MM

3

VF-3-60-202

AIR FLUE SAFETY VENT 500MM

4

VF-3-60-201

AIR FLUE SAFETY VENT 250MM

5

VF-3-60-245

AIR FLUE SAFETY VENT 45 ELBOW

6

VF-3-60-246

AIR FLUE ELBOW SUPPORT BRACKET
KIT

7

VF-3-60-003

AIR FLUE SUPPORT 2

8

VF-3-60-002

AIR FLUE SUPPORT 1

9

VF-3-60-108

AIR FLUE STOVE PIPE TO SAFETY VENT
TRANSITION

10

VF-3-60-105

AIR FLUE STOVE PIPE 620-1080MM
ADJUSTABLE

11

VF-3-60-104

AIR FLUE STOVE PIPE 420-610MM
ADJUSTABLE

12

VF-3-60-103

AIR FLUE STOVE PIPE 240-280MM
ADJUSTABLE

13

VF-3-60-107

AIR FLUE STOVE PIPE 1200MM

14

VF-3-60-106

AIR FLUE STOVE PIPE 1000MM

15

VF-3-60-100

AIR FLUE STOVE PIPE 250MM

16

VF-3-60-145

AIR FLUE STOVE PIPE 45 ELBOW

17

VF-3-60-090

AIR FLUE STOVE PIPE T SECTION

18

VF-3-60-091

AIR FLUE ADJUSTABLE SNORKEL

19

VF-3-60-110

AIR FLUE CEILING RING - 80MM

Summary of Contents for VisionLINE AIR

Page 1: ...Safety Vent AIR Instruc on Manual...

Page 2: ...sis ng of flues in 150 mm of 0 6 mm 316L stainless steel insulated with 25 mm Morgan Frax ceramic insula on with a density of 128 kg m air gap of 20 mm 20 mm Morgan Frax ceramic insula on 128 kg m and...

Page 3: ...ystems and Flue System Clearances In Australia and New Zealand this flue system can ONLY be used for solid fuel systems Wood Preparation Before installation planning is essential for an efficient safe...

Page 4: ...cannot be achieved additional frame work in the roof will be required to house the flue bracing bracket Please ensure clearances are met when fi ing the flue bracing bracket and constructing any addit...

Page 5: ...he locked position VisionLINE safety vent AIR CANNOT be cut if you require smaller sections please contact your distributor Roof Penetration Once the safety vent AIR flue has passed though the roof th...

Page 6: ...the flue system is compatible with direct spigot air intake If the fireplace uses a rear or floor entry intake system a T piece section can be used Part number VF 3 60 090 as the final VL stove pipe s...

Page 7: ...eight requirements per AS NZS 2919 Elbow support bracket kit VF 3 60 246 Use of bends 45o Bends can be used on this flue system Either the stove pipe flue or the VisionLINE safety vent flue can be off...

Page 8: ...UPPORT 2 8 VF 3 60 002 AIR FLUE SUPPORT 1 9 VF 3 60 108 AIR FLUE STOVE PIPE TO SAFETY VENT TRANSITION 10 VF 3 60 105 AIR FLUE STOVE PIPE 620 1080MM ADJUSTABLE 11 VF 3 60 104 AIR FLUE STOVE PIPE 420 61...

Page 9: ...D 65 mm E 193 mm 148 5 Ceiling Ring VF 3 60 110 Flush spigot adapter 193 L 30 Adjustable Stove pipe 193 L 30 Stove pipe Part number Joined length Total length VF 3 60 100 220mm 250mm VF 3 60 106 970mm...