24
Lighting after installation
The Jetmaster should not be run hard until all cement and plasterwork is completely dry and cured. When
installation has involved building in cement mortar allow: -
A. 7 days drying time if the house has other forms of heating.
b. At least 14 days if the installation is in a new or unoccupied property, or is fitted into a completely new
chimney breast.
Chimney Sweeping
We recommend that chimneys should be swept at least once a year during the burning season. More frequent
sweeping may be necessary where fires are burned throughout the year or where low-grade woods or bituminous
coal are used as fuels. The chimney can be swept through the fire. The fire is provided with removable tertiary air
tubes and board baffles to facilitate chimney sweeping and for the removal of soot from the unit. See Servicing
Instructions.
Handing Over
•
Read the Users instructions and instruct the user on the operation of the fire and cleaning methods.
Leave instructions with the user.
•
The user should be told that any odours are due to the newness of materials and should disperse after a
few hours operation.
•
The user should be informed that the fire should be serviced annually and the chimney checked for flue
pull and blockage.
Inform the customer of the requirement to fit a carbon monoxide alarm and the need for regular testing
of such a device
Advise the customer on the operation of the air control lever in a smoke controlled area and that the low
rate stop must be left fitted in position.
Advise the customer on the importance of an adequate air supply to the room
Advise the customer on the importance of regular servicing and chimney sweeping
Advise the customer on the door opening/closing procedure and the importance of always wearing a
heat proof glove when operating the controls, the door and re-fuelling the fire.
The serial number is located on the data plate behind the door on the front of the fire
Finally, record the serial number and installer/supplier details at the front of this
instruction book.
Data Plate
The data information can be found on the data badge located at the left side of the inner fire box.
The plate can be rotated out as shown in the photo the data can be read easier if the door is removed.
To remove the door, see section on door removal/replacement.