Page 9
2.
PROGRAM SCREENS
Pressing the left arrow in any of the program screens will save the entire program to the permanent
memory of the 9700W.
WIRE START DLY
If the wire is started by the external contact this is the delay after
getting the signal from when the wire starts to move. If started by
the Start button on the panel this value is dismissed and the wire
starts immediately. Minimum value is 0.0, Maximum value is
10.0.
WIRE STOP DLY
If the wire is started by the external contact this is how long after
the contact has been removed before the wire will start begin
retract. Otherwise retracts starts when stop is pressed. Minimum
value is 0.0, Maximum value is 10.0.
RAMP TIME
After the wire starts feeding, this is the time the wire will ramp up
from 0.0 to its programmed speed. This is most likely used in hot
wire applications when high wire speeds are used to ramp wire
with the heat put into the part. The line will only appear if
Configuration Mode / Ramp Enable is Yes. Minimum value is 0.0,
Maximum value is 10.0.
AUX1 PROGRAM SUB MENU SCREEN
If the right button is pressed you will go into the AUX1 sub menu.
This screen will only appear if Configuration Mode / AUX1 name
has been assigned a name and then that name will appear in the
menu. See AUX1-3 section for details of this sub menu.
PROGRAM
UNLOCKED
0.0
0.0
ADJUST
WIRE START DLY
WIRE STOP DLY
PROGRAM
0.0
0.0
0.0
WIRE START DLY
WIRE STOP DLY
RAMP TIME
PROGRAM
0.0
0.0
ll
u
WIRE STOP DLY
RAMP TIME
AUX1
PROGRAM
0.0
ll
u
ll
u
RAMP TIME
AUX1
AUX2