JETI model Max BEC 2D Manual Download Page 6

voltage. Please note that these values are deleted automatically or can be deleted manually 

using the 

Erase Data

 menu option. The values are automatically erased when the unit is switched 

on and the input voltages exceed those specified in the 

Trigger Level

 menu option.

Accum. A MIN/MAX

 - Shows the minimum and maximum voltage of the battery connected to 

input A.

Accum. B MIN/MAX

 - Shows the minimum and maximum voltage of the battery connected to 

input B.

Temp. MIN/MAX

 - Shows the minimum and maximum temperature of the Max BEC 2D.

4.3 SETTING - Configuration Options

SETTING 

- By pressing the 'D' (Down) button, we can see the individual parameter settings of the 

Max BEC 2D.

Erase Data

 - By simultaneously pressing the Left and Right button of the Jeti Box, all minimum 

and maximum recorded values are erased (See also section 4.2)

Trigger Level

 - Set the voltage values, the first overshoot of which, the previously recorded 

minimum and maximum values are erased and recording begins again (See also section 4.2)

Output (x.x) Volt - 

Set the output voltage of the BEC. Note that the output voltage of the BEC can 

be set by jumper or programmed using the Jeti Box. By pushing the 'L' (Left) button, the BEC can 

be configured purely by Jumper. By pushing 'R' (Right), the BEC output voltage can be set 

directly from the Jeti Box, overriding the physical position of the Jumper.

Beep Volt. Alarm

 - Set the letter of the alphabet to be acoustically signalled from the transmitter 

module when the input voltage falls below that specified by 

Trig. Level for WARN LED

Beep Temp. Alarm 

- Set the letter of the alphabet to be acoustically signalled from the transmitter 

module when the temperature of the BEC exceeds the limit specified by 

Temp. Alarm

 (In the 

Alarm menu - See section 4.4)

Trig. Level for WARN LED - 

The input voltage at which the red warning LED on the magnetic 

switch-plate and on the BEC should become active. This is also the voltage at which the first 

green LED should deactivate.

Step Value - 

The voltage value of each step between the green input voltage LED's on the BEC 

(5.5-8.4V). The table below shows an example, assuming a step value of 0.4V and a trigger level 

of 6.6V: 

Summary of Contents for Max BEC 2D

Page 1: ...age can be configured and alarms can be set for input voltage and temperature as required The system uses the 2 4GHz band to communicate which allows not only data transmission but also the receiving...

Page 2: ...BEC is active The Red LED indicates a warning condition If the green LED is blinking this indicates that the magnetic key is present but the unit is not switched on If the green LED is continuously ac...

Page 3: ...se wire of at least 1mm2 diameter or larger depending on your anticipated load to the MPX output connector of the BEC or use the Jeti MPX 3xJR cable available separately The Duplex EPC receivers such...

Page 4: ...g this into the socket marked Ext on the Duplex receiver Connect the supply battery to the BEC not forgetting to connect the power output of the BEC to your receiver Now the Jeti Box can be connected...

Page 5: ...the screen shows the identification of the unit the temperature and the voltage of each supply battery The active power supply input is marked by a character By pressing the D Down button on the Jeti...

Page 6: ...ain See also section 4 2 Output x x Volt Set the output voltage of the BEC Note that the output voltage of the BEC can be set by jumper or programmed using the Jeti Box By pushing the L Left button th...

Page 7: ...ll be sounded by the transmitter module for battery B See 4 3 SETTING Configuration Options Temp Alarm Set the temperature at which point the alarm specified by the Beep Temp Alarm setting will be sou...

Page 8: ...zed the orientation of the magnetic key is important when being offered to the switch plate The magnet is supplied with an aluminium housing which marks the correct orientation in which it should be o...

Page 9: ...ed Always follow the same procedure when switching on off To switch on first connect the batteries and then use the magnetic switch to activate the unit To switch off always use the magnetic switch to...

Page 10: ...imum Input Voltage 16 V Number of possible power supply batteries 1 or 2 Adjustable Output Voltage 5 0 6 0V 0 1V Steps Maximum current pulse 20A Continuous current 12A Quiescent current 240 A Maximum...

Page 11: ...ion that it has been operated as per these instructions and there is no mechanical damage All servicing and repairs during and after the warranty period is carried out by the manufacturer The manufact...

Page 12: ......

Reviews: