The Max BEC 2D can be powered by up to two batteries. These can vary by cell-count and 

chemistry and the BEC will always take power from the battery with the highest voltage. If both 

batteries have the same voltage, then the BEC will take power from both batteries together. LED 

Batt. A and/or LED Batt. B will indicate which battery the power is being drawn from. This can 

also be determined from the Jeti Box.

If only one battery is to be used, it can be connected to battery input A or input B.

 

To connect your device(s) to the BEC, either solder your wires (Please use wire of at least 1mm2 

diameter or larger, depending on your anticipated load) to the MPX output connector of the BEC 

or use the Jeti MPX/3xJR cable, available separately. The Duplex EPC receivers, such as the R6 

EPC, R8 EPC, R12, R14 and R18 are already fitted with a compatible MPX plug.

 

3.2 Communication with the Max BEC 2D

3.2.1 Connecting to the Jeti Box

Connect the BEC to the Jeti Box using the red JR connector from the BEC. Plug this into the 

appropriate socket of the Jeti Box (The socket marked signal, +, -).

Connect the power-supply battery to the BEC and switch-on the BEC using the magnetic switch.

For this setup, there is no need to connect a supply battery to the Jeti Box as it will be powered 

by the BEC. There is no wireless data transfer in this scenario.

Summary of Contents for Max BEC 2D

Page 1: ...age can be configured and alarms can be set for input voltage and temperature as required The system uses the 2 4GHz band to communicate which allows not only data transmission but also the receiving...

Page 2: ...BEC is active The Red LED indicates a warning condition If the green LED is blinking this indicates that the magnetic key is present but the unit is not switched on If the green LED is continuously ac...

Page 3: ...se wire of at least 1mm2 diameter or larger depending on your anticipated load to the MPX output connector of the BEC or use the Jeti MPX 3xJR cable available separately The Duplex EPC receivers such...

Page 4: ...g this into the socket marked Ext on the Duplex receiver Connect the supply battery to the BEC not forgetting to connect the power output of the BEC to your receiver Now the Jeti Box can be connected...

Page 5: ...the screen shows the identification of the unit the temperature and the voltage of each supply battery The active power supply input is marked by a character By pressing the D Down button on the Jeti...

Page 6: ...ain See also section 4 2 Output x x Volt Set the output voltage of the BEC Note that the output voltage of the BEC can be set by jumper or programmed using the Jeti Box By pushing the L Left button th...

Page 7: ...ll be sounded by the transmitter module for battery B See 4 3 SETTING Configuration Options Temp Alarm Set the temperature at which point the alarm specified by the Beep Temp Alarm setting will be sou...

Page 8: ...zed the orientation of the magnetic key is important when being offered to the switch plate The magnet is supplied with an aluminium housing which marks the correct orientation in which it should be o...

Page 9: ...ed Always follow the same procedure when switching on off To switch on first connect the batteries and then use the magnetic switch to activate the unit To switch off always use the magnetic switch to...

Page 10: ...imum Input Voltage 16 V Number of possible power supply batteries 1 or 2 Adjustable Output Voltage 5 0 6 0V 0 1V Steps Maximum current pulse 20A Continuous current 12A Quiescent current 240 A Maximum...

Page 11: ...ion that it has been operated as per these instructions and there is no mechanical damage All servicing and repairs during and after the warranty period is carried out by the manufacturer The manufact...

Page 12: ......

Reviews: