12
MVP Group Corp - 5659 Royalmount Ave., Montreal, QC, Canada H4P 2P9
Tel: 514.737.9701 / 888.275.4538 - Fax: 514.342.3854 / 877.453.8832
[email protected] - www.mvpgroupcorp.com
t
rouble
or
s
ItuatIon
c
ause
r
emedy
A. Unit does not run
1. Sliding cover open
1. Close sliding cover
2. Out of chemicals
2. Replace and prime empty chemicals
3. No power (Power light “off”)
3. Check power source
4. Defective switch panel
4. Replace switch panel
5. Wire connections poor, loose, or broken
5. Re-crimp and/or replace wire connection
B. Unit experiences a delay (up to 15 sec-
onds) before beginning a cycle
1. Incoming water does not reach minimum
operating temperature
1. Check temperature of water source
C. Conveyor runs but holding tank not
filling
1. Water “off”
1. Turn water “on”
2. Bad water valve
2. Test valve, replace if necessary
D. Conveyor moves intermittently
1. Glassware or debris blocking rotation of
conveyor
1. Clear obstruction
2. Worn drive coupling
2. Replace drive coupling
E. Water recirculating, conveyor not
moving
1. Obstruction in tank area
1. Remove obstruction
2. Conveyor not engaged with conveyor
drive shaft
2. Rotate conveyor until it engages
3. Worn drive coupling
3. Replace drive coupling
4. Defective drive motor
4. Replace drive motor
F. Water
not recirculating
1. Completely plugged pump inlet screen
1. Clean pump inlet screen
2. Defective recirculating pump
2. Replace recirculating pump
G. Water leaking from recirculating
pump housing - water on floor
1. Defective pump seal
1. Replace pump
2. Pump housing cracked
2. Replace pump
H. Glasses slimy or soapy at end of cycle
1. Sanitizer feed line in detergent container
1. Clean line and place in proper container
2. Improper Rinse Aid setting
2. Adjust chemical setting
I. Recirculating water pressure low
1. Spray box not latched properly
1. Latch spray box properly
2. Partially plugged pump inlet screen
2. Clean pump inlet screen
Refer to page 8 cleaning instructions
3. Missing or worn spray box gasket
3. Replace gasket
J. Detergent, sanitizer, and/or rinse aid
not feeding properly
1. Chemical container is empty
1. Refill or replace container(s)
2. Feed lines will not fill
2. Replace defective parts. Notes: The deter-
gent, sanitizer, or rinse aid product advanc-
es in the line on each stroke of the pump.
The product should hold position between
strokes. If the product falls back toward the
supply container, one or more of the fol-
lowing conditions may exist:
a. Debris in pump
b. Split feed line
c. Bad pump tube
Replace parts as necessary
K. Poor washing results
1. Clogged spray nozzles and dirty holding
tank
1. Clean unit -see page 8 cleaning instructions
2. Detergent container empty
2. Fill container
3. Poor water conditions
3. Have filter or softener installed
4. Chemicals not adjusted properly
4. Call chemical technician
5. No hot water
5. Check temperature of water source
t
rouble
s
hootInG
G
uIde
Summary of Contents for XG-37
Page 5: ...Operation Manual XG 37 Glasswasher 2012 Jet Tech Rev 13 01 12...
Page 21: ...Parts Directory XG 37 GlassWasher...
Page 24: ...5 InterIor and exterIor ComPonents 3 7 8 2 9 11 1 10 12 17 13 14 15 18 16...
Page 26: ...eleCtrICal ComPonents 7 3 4 10 11 5 7 8 6 9 1 2 19 16 20 14 21 18 17 15 28 27 26 12 13 24...
Page 28: ...reCIrCulatInG PumP and related Parts 9 6 7 1 2 3 8 4 5 9 10...
Page 30: ...PerIstaltIC PumP ChemICal tubInG and related Parts 11 10 12 11 1 8 7 9 13 3 16 2 15 14...
Page 32: ...drIve assembly ComPonents 13 1 10 7 8 2 3 6 11 4 9 10 8 5...