background image

XG-37

ROTARY BAR

GLASSWASHER

Standard Features :

Fill and dump style cycle uses less water and energy than traditional rotary glasswashers. 

Conveyor easily lifts out

for cleaning access.

Drain stopper is controlled by a quiet and

reliable gear motor with linkage cam

instead of a noisy solenoid valve.

Chemical fill is easily visible by

sliding the cover open during the

fill portion of the wash and rinse cycle.

Stationary spray box simply

unlatches for easy visual

inspection and cleaning.

Incoming water line has built-in
air gap so no separate vacuum

breaker accessory is required.

Special mounting bracket allows
for easy service access to water

recirculating pump.

Unit plugs into standard 120V electrical outlet for an easy installation. 
Computer controlled fill cycle allows for 75°F (24°C) rinse, providing clean glasses that are cool to the touch.
The sliding cover and cold water rinse prevent steam from escaping during and after the cycle.
Unique drainboard top provides integrated glassware landing area.
Exclusive design with side notch provides space for three one-gallon chemical containers within the 24" by 24" foot print. 
Conveyor advance switch rotates conveyor one-half turn for easy loading and unloading of glassware. 
Covers and drainboard top are easily removable for cleaning access.
Pre-programmed de-liming cycle for easy removal of mineral deposits during maintenance (de-liming agent must be added). 
Conveyor and stationary spray box are easily removed for cleaning and visual inspection. 
Automatic peristaltic metering pumps accurately dispense detergent, sanitizer, and rinse aid. 

Mechanicals :

Dimensions :

3  = COLD WATER

2  = HOT WATER

1  = DRAIN

4  = ELECTRICAL

PLAN VIEW

Sliding

Door

Open

FRONT VIEW

SIDE VIEW

NOTE: 1. In  all  cases,  consult  local  plumbing,  electrical  and  health 

codes  for  regulations  which  may  not  be  consistent  with  the 
information on the front of this specification sheet

2. The utility connections are made from the floor at the bottom 

of the unit approximately 7" to 8" high.

3. The Jet-Tech policy of constant quality improvement means 

specifications are subject  to change without notice.

24"

24"

10-3/32"

7"

14.75"

30"

30.75"

6"

24"

7"

10.625"

24"

2

3

1

4

4.312"

5"

10.5"

7.5"

9"

15.531"

MVP GROUP CORPORATION

5659 Royalmount Ave.   Montreal   QC, Canada   H4P 2P9
Tel: 514.737.9701 / 888.275.4538
Fax: 514.342.3854 / 877.453.8832
[email protected] 

www.mvpgroupcorp.com

Summary of Contents for XG-37

Page 1: ...top provides integrated glassware landing area Exclusive design with side notch provides space for three one gallon chemical containers within the 24 by 24 foot print Conveyor advance switch rotates...

Page 2: ...nel includes Conveyor advance switch that rotates conveyor one half turn for easy loading and unloading of glassware Priming switches for easy priming of chemical pumps De liming cycle for easy remova...

Page 3: ...tanks 16 gauge stainless steel parts include leg mounting brackets and legs 11 gauge stainless steel parts include drive wheel Service Access Front panel is removable for service Detergent Sanitizer...

Page 4: ...ons 3 COLD WATER 2 HOT WATER 1 DRAIN 4 ELECTRICAL PLAN VIEW Sliding Door Open FRONT VIEW SIDE VIEW NOTE 1 In all cases consult local plumbing electrical and health codes for regulations which may not...

Page 5: ...Operation Manual XG 37 Glasswasher 2012 Jet Tech Rev 13 01 12...

Page 6: ...37 Parts Identification 3 Start Up Instructions 4 5 Water Level Temperature Adjustment Procedure 4 Chemical Adjustment Procedure 5 Control Panel Operation 6 Wash Cycle Description 6 Wiring Diagram 7 C...

Page 7: ...more about this simple machine Note the Simplicity Function Design Wash Hot water and a preset portion of detergent join in the tank During operation hot soapy water is pumped in a forceful but gentle...

Page 8: ...mum drainage 3 Electrical a 120V single phase 60Hz 6 foot grounded cord included b A dedicated 15 amp circuit is recommended c Power requirements 3 5 amps 4 Detergent a Extra heavy duty non foaming co...

Page 9: ...e out holder for chemicals Water inlet lines Drainstopper cam and linkage arm Circuit Board XG 37 Part Identification Front Panel Removed Top View 1 Main section 11 Inlet screen Drain hole for drainbo...

Page 10: ...mplete cycle or dump clean water in the tank after using the prime switches Undiluted chemicals will damage stainless steel 4 Fill Level Adjustment Cycle the glasswasher to check water fill level wate...

Page 11: ...cover open will end the cycle and drain the tank after 30 seconds and cycle can be re started to check rinse temperature again Once rinse water temperature is correct continue with Step 6 6 Chemical C...

Page 12: ...he sliding cover can be opened during fill to visually verify chemicals are being injected into the rinse water 10 The rinse cycle automatically starts once the tank if full Opening the sliding cover...

Page 13: ...ump HOT HOT Neutral Neutral 120 Vac 120 Vac MC4003491TS Conveyor Soft Start Y Y W W B R BARE C NO NO NC NC C B B Y Green Light Red Light R W B 1 2 3 4 5 6 7 8 9 10 Det Prime San Rin Prime De Lime Cycl...

Page 14: ...aning procedures consist of the following steps 1 Remove drainboard insert drainboard pan sliding cover and inner cover Wipe down each part as necessary 2 Remove the conveyor wheel Any large debris fo...

Page 15: ...mpty out any debris that may have passed through the tank screen 5 Use a damp cloth to wipe down the entire wash tank For more stubborn stains use a nylon brush or a Scotch Brite Stainless Steel Clean...

Page 16: ...st Kit as recommended by your chemical supplier is required for proper chemical adjustment Follow kit instructions to test Sanitizer Titrating Instructions After the water has agitated during the rins...

Page 17: ...condition of water varies by region the chemical pumps are not pre set at the factory The chemical pumps must be adjusted at start up to achieve the proper titration levels or the machine may not pro...

Page 18: ...en 2 Defective recirculating pump 2 Replace recirculating pump G Water leaking from recirculating pump housing water on floor 1 Defective pump seal 1 Replace pump 2 Pump housing cracked 2 Replace pump...

Page 19: ...thorized Jet Tech service agency and that this agency installed an original and genuine Jet Tech part in the machine Any repair work performed by a nonauthorized service depot remains the sole respons...

Page 20: ...ump HOT HOT Neutral Neutral 120 Vac 120 Vac MC4003491TS Conveyor Soft Start Y Y W W B R BARE C NO NO NC NC C B B Y Green Light Red Light R W B 1 2 3 4 5 6 7 8 9 10 Det Prime San Rin Prime De Lime Cycl...

Page 21: ...Parts Directory XG 37 GlassWasher...

Page 22: ...ents 5 6 Electrical Components 7 8 Recirculating Pump and Related Parts 9 10 Peristaltic Pump Chemical Tubing and Related Parts 11 12 Drive Assembly Components 13 14 Accessories 14 Plumbing Components...

Page 23: ...s and draInboard toPs Part no desCrIPtIon 1 01001559 Sliding cover 2 01001560 Drainboard top 3 01001440 Insert drainboard top 4 01001443 Inner cover 5 01001552 Slide plastic sliding cover 2 required 1...

Page 24: ...5 InterIor and exterIor ComPonents 3 7 8 2 9 11 1 10 12 17 13 14 15 18 16...

Page 25: ...nnel cover mounting 1 4 20 zinc 8 01001413 Cover overflow channel 9 01001435 Cover drain tank mist 10 00000153 Screw phillips pan head 10x1 2 SS 1 required 11 01001475 Tank complete includes all welde...

Page 26: ...eleCtrICal ComPonents 7 3 4 10 11 5 7 8 6 9 1 2 19 16 20 14 21 18 17 15 28 27 26 12 13 24...

Page 27: ...ture gauge sensor probe 13 00000026 Nut retaining plate star 6 01000641 Washer retaining plate star 6 14 01000669 Plug three wire 15 01000547 Receptacle three wire 16 01000670 Plug solderless terminal...

Page 28: ...reCIrCulatInG PumP and related Parts 9 6 7 1 2 3 8 4 5 9 10...

Page 29: ...s truss head 4 required 3 00000000 Clamp hose 8 required 4 00000015 Hose 1 ID x 1 1 4 OD x 1 8 2 ft required 5 01000906 Elbow grey plastic high pressure braid 2 required 6 01000623 Nut 1 4 20 Large Fl...

Page 30: ...PerIstaltIC PumP ChemICal tubInG and related Parts 11 10 12 11 1 8 7 9 13 3 16 2 15 14...

Page 31: ...aid with fittings 1 8 ID 7 01000517 Tubing clear 1 8 ID x 1 4 OD per foot 8 01000739 Grommet three hole rubber chemical inlet 9 01001520 Inlet detergent sanitizer or rinse aid 1 8 x 1 8 10 01000485 De...

Page 32: ...drIve assembly ComPonents 13 1 10 7 8 2 3 6 11 4 9 10 8 5...

Page 33: ...her head 4 required attaches motor to motor mount 6 01001473 Bracket motor mounting 7 00000041 Bolt 1 4 20 x 5 8 hex washer head 4 required attaches motor mount to tank 8 01000956 Hub flexible shaft c...

Page 34: ...PlumbInG ComPonents 15 13 21 20 30 22 31 12 11 24 8 2 18 23 14 29 16 5 3 15 4 8 1 7 27 25 8 28 6 26 9 17 19 10...

Page 35: ...steel 15 01000767 Drain stopper ball grey rubber reversible 16 01000691 Drain stopper assembly consists of 01000768 and 01000767 17 01000595 Drive motor drain stopper 10 RPM same as drive wheel 18 00...

Reviews: