operation instructions
page 3
2. Technical data
Power source
MIG 296
MIG 326
MIG 406
MIG 506
Supply voltage, 50/60 Hz
400 V, 3-phase 400 V, 3-phase 400 V, 3-phase 400 V, 3-phase
Max. current consumption
17 A
24 A
32 A
41 A
Fuse
16 A slow
20 A slow
25 A slow
32 A slow
Max. power draw
12 kVA
16 kVA
22 kVA
28 kVA
Cos phi
0.85
0.85
0.85
0.85
Set-point range
30 - 290 A
50 - 320 A
50 – 400 A
60 – 500 A
Operating voltage
16 - 29 V
16 - 30 V
16 – 34 V
17 – 39 V
Open-circuit voltage
19 - 45 V
20 - 48 V
20 – 52 V
23 – 61 V
Voltage steps
12 x fine
24
2 x coarse,
12 x fine
24
2 x coarse,
12 x fine
24
2 x coarse,
12 x fine
Duty cycle 35 %
290 A / 29 V
Duty cycle 50 %
500 A / 39 V
Duty cycle 60 %
260 A / 27 V
320 A / 30 V
400 A / 34 V
440 A / 36 V
Duty cycle 100 %
220 A / 25 V
250 A / 27 V
250 A / 27 V
320 A / 30 V
System of protection
IP 23
IP 23
IP 23
IP 23
Insulation class
H (180° C)
H (180° C)
H (180° C)
H (180° C)
System of cooling
F
F
F
F
Weight incl. wire feed unit
120 kg
155 kg
169 kg
179 kg
Dimensions L x W x H (mm)
1040 x 460 x 720 excl. case
1040 x 460 x 1040 incl. case
Noise level
< 70 dB(A)
→
Manufactured in accordance with European Standards EN 60 974-1 and EN 60 974-10
Summary of Contents for MIG 296
Page 18: ...Betriebsanleitung Seite 15 11 Ersatzteile Abb 11 1 Frontansicht ...
Page 20: ...Betriebsanleitung Seite 17 Abb 11 2 Seitenansichten ...
Page 22: ...Betriebsanleitung Seite 19 Abb 11 3 Koffer ...
Page 36: ...operation instructions page 7 4 Control elements ...
Page 44: ...operation instructions page 15 10 Spare Parts Picture 10 1 Frontview ...
Page 46: ...operation instructions page 17 Picture 10 2 Sideview ...
Page 48: ...operation instructions page 19 Picture 10 3 wire feed case ...