Step # 5
Replacing Cup motor or Cup sensor
The molex connection for the LED
board can be found on the underside
of the board in the area specified in
the circle, the connector should look
like the one in the picture to the
lower right.
DIAGNOSE MOTOR / SENSOR FAULT AND REPLACEMENT PROCEDURE
Step # 4
Replacing Cup motor or Cup sensor
After removal of the eight screws
holding down the pyramind playfield
acrylic, pull up on the white acrylic,
you will have some resistance
because of the rubbr cup lips. Once
the acrylic has been removed there
are four 3 mm hex headed screws
that need to be removed before
removal of the table top graphic
acrylic.
After table top acrylic has been
removed there are three groups of
three molex connections that need to
be removed from each side of the
main cup assembly, one molex that
attaches to the underside of the LED
cup PCB board (green light board),
and a ground strap, that need to be
disconnected before the main cup
assembly can be removed.
Step # 6
Replacing Cup motor or Cup sensor
Jennison Entertainment Technologies
Power Pong Service Manual