background image

4

Cabinet Dimensions

IMPORTANT:

 If installing a range hood or microwave hood 

combination above the cooktop, follow the range hood or 

microwave hood combination installation instructions for 

dimensional clearances above the cooktop surface.

Standard Install Dimensions Table

NOTE:

 When pairing cooktops, this option is recommended only 

with stainless steel or framed cooktops.

Units

Upper Cabinet 

Width (A)

Cutout 

Width (J)

One 15" (38.1 cm) unit

15" 

(38.1 cm)

14

3

/

8

"  

(36.5 cm)

Two 15" (38.1 cm) units

30" 

(76.2 cm)

29

3

/

8

"  

(74.6 cm)

Three 15" (38.1 cm) units

45" 

(114.3 cm)

44

7

/

16

(112.9 cm)

Four 15" (38.1 cm) units

60"  

(152.4 cm)

59

7

/

16

(151.0 cm)

24" (61.0 cm) cooktop

24" 

(61.0 cm)

22

31

/

32

(58.3 cm)

24" (61.0 cm) cooktop and 

one 15" (38.1 cm) unit

39" 

(99.1 cm)

38

3

/

16

"  

(97.0 cm)

24" (61.0 cm) cooktop and 

two 15" (38.1 cm) units

54" 

(137.2 cm)

53

3

/

8

(135.6 cm)

30" (76.2 cm) cooktop

30" 

(76.2 cm)

28

31

/

32

(73.6 cm)

30" (76.2 cm) cooktop and 

one 15" (38.1 cm) unit

45"  

(114.3 cm)

44

3

/

16

(112.2 cm)

30" (76.2 cm) cooktop and 

two 15" (38.1 cm) units

60"  

(152.4 cm)

59

3

/

16

(150.3 cm)

36" (91.4 cm) cooktop

36" 

(91.4 cm)

34

31

/

32

(88.8 cm)

36" (91.4 cm) cooktop and 

one 15" (38.1 cm) unit

51"  

(129.5 cm)

50

3

/

16

(127.5 cm)

NOTE:

 After making the countertop cutout, some installations 

may require notching down the base cabinet side walls to clear 

the cooktop base. To avoid this modification, use a base cabinet 

with sidewalls wider than the cutout.
If cabinet has a drawer, a 5

1

/

2

" (14.0 cm) depth clearance from 

the countertop to the top of the drawer (or other obstruction) 

in base cabinet is required.

Flush Installation Dimensions

All cooktops can be mounted with a frameless standard 

installation sitting on top of the countertop surface or flush with 

the top of the countertop.
If the cooktop is to be mounted flush with the countertop, a 

recessed area surrounding the cooktop cutout must be provided 

with the following dimensions: 

1. 

11/64" (4.3 mm) recessed depth is needed for the SS Frame 

Model (see dimension E).

2. 

7/32" (5.6 mm) recessed depth is needed for the Glass 

Model without a frame.

NOTE:

 This option is not recommended for countertops with 

a molded backsplash. Do not silicone seal in place.

D

A

E

I

J

K

H

L

C

F

B

G

A.  Minimum upper cabinet width. See the “Standard Install Dimensions” 

table.

B.  Combustible area above countertop (shown by dashed box above) 
C.  30" (76.2 cm) minimum clearance between top of cooktop platform 

and bottom of uncovered wood or metal cabinet (24" [61.0 cm] 

minimum clearance if bottom of wood or metal cabinet is covered 

by not less than 1/4" [0.06 mm] flame retardant millboard covered 

with not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless 

steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)

D.  13" (33 cm) recommended upper cabinet depth
E. 2

5

/

6

" (5.9 cm) minimum distance to front countertop edge

F. 20

3

/

8

" (51.8 cm)

G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop 

within minimum horizontal clearances to cooktop

H.  Junction box or outlet: 7" (17.8 cm) minimum from top of countertop
I.  Junction box or outlet: 9" (23.0 cm) maximum from right side of 

cabinet

J.  See the “Standard Install Dimensions” Table
K.  6" (15.2 cm) minimum side wall clearance
L. 2

5

/

16

" (5.9 cm) minimum distance to rear combustible surface

Summary of Contents for JIC4724HB

Page 1: ...teur des installations lectriques local W11251690A COOKTOP SAFETY 1 INSTALLATION REQUIREMENTS 3 Tools and Parts 3 Location Requirements 3 Electrical Requirements 5 INSTALLATION INSTRUCTIONS 6 Prepare...

Page 2: ...2 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS...

Page 3: ...2 7 cm beyond the bottom of the cabinets The cooktop must be installed in a level countertop Ovens approved for this type of installation will have an approval label located on the top of the oven If...

Page 4: ...e cabinet is required Flush Installation Dimensions All cooktops can be mounted with a frameless standard installation sitting on top of the countertop surface or flush with the top of the countertop...

Page 5: ...s recommended that a qualified electrical installer determine that the ground path and wire gauge are in accordance with local codes Check with a qualified electrical installer if you are not sure the...

Page 6: ...Installation Write down the model and serial numbers before installing the cooktop Both numbers are located on the center underside of the burner box Unpack the parts supplied with your cooktop The p...

Page 7: ...EC mobile homes and recreational vehicles New constructions and in Canada 1 Disconnect power 2 Remove junction box cover if present 3 Connect the 2 red wires B together using a UL listed wire connecto...

Page 8: ...liquid household cleaner and warm water to clean cooktop before use Dry thoroughly with a soft cloth For more information see the Cooktop Care section of the Use and Care Guide 5 Read the Cooktop Use...

Page 9: ...9 S CURIT DE LATABLE DE CUISSON...

Page 10: ...ue d incendie et vacuer ad quatement les gaz veiller acheminer l air aspir par un conduit jusqu l ext rieur ne pas d charger l air aspir dans un espace vide du b timent comme une cavit murale un plafo...

Page 11: ...on doit tre install e dans un plan de travail qui est d aplomb Les fours homologu s pour ce type d installation comportent une tiquette d homologation plac e sur le dessus du four Si vous ne trouvez p...

Page 12: ...struction dans l armoire inf rieure Dimensions pour un panneau en affleurement Toutes les tables de cuisson peuvent tre mont es en utilisant une installation standard sans ch ssis reposant sur la surf...

Page 13: ...ur distinct de liaison la terre lorsque les codes le permettent il est recommand qu un lectricien qualifi v rifie que la liaison la terre et le calibre des conducteurs sont conformes aux codes locaux...

Page 14: ...L pour raccorder le cuivre l aluminium INSTRUCTIONS D INSTALLATION Pr paration de la table de cuisson pour l installation Prendre note des num ros de mod le et de s rie avant d installer la table de c...

Page 15: ...terre par l interm diaire du conducteur neutre en cas de nouvelle installation avec alimentation par un circuit secondaire 1996 NEC dans les r sidences mobiles et les v hicules r cr atifs dans une no...

Page 16: ...vant d utiliser la table de cuisson utiliser une solution douce de nettoyant domestique et d eau ti de pour la nettoyer S cher soigneusement avec un chiffon doux Pour plus de renseignements voir la se...

Reviews: