background image

6

Electrical Requirements

If codes permit and a separate ground wire is used, it is 

recommended that a qualified electrical installer determine that 

the ground path and wire gauge are in accordance with local 

codes.
Check with a qualified electrical installer if you are not sure the 

cooktop is properly grounded.
Make sure that the electrical connection and wire size are 

adequate and in conformance with the National Electrical Code, 

ANSI/NFPA 70—latest edition or CSA Standards C22.1—94, 

Canadian Electrical Code, Part 1 and C22.2 No. O-M91-latest 

edition, and all local codes and ordinances.
A copy of the above code standards can be obtained from:

National Fire Protection Association 

1 Batterymarch Park 

Quincy, MA 02169-7471

CSA International 

8501 East Pleasant Valley Road 

Cleveland, OH 44131-5575

Before You Make the Electrical Connection:

To properly install your cooktop, you must determine the type of 

electrical connection you will be using and follow the instructions 

provided for it here.

 

A 3-wire or 4-wire, single phase, 240-volt, 60 Hz, AC-only 

electrical supply is required on a separate, 20 AMP, 2-pole 

breaker, 240-/208-volt, 50/60 Hz AC-supply circuit fused on 

both sides of the line. The model/serial/rating plate is located 

on the metal cabinet underneath the cooktop. See the 

following illustration.
NOTE: A separate 20-amp circuit fused on both sides of the 

line can be used for 20-amp, 2-pole breaker, 240-/208-volt, 

50/60 Hz AC-supply.

 

The cooktop is rated 240/208 volts. This model has a neutral 

(white) wire.

 

The cooktop should be connected directly to the junction 

box through flexible, conduit shielded wire. No alternative is 

permissible. The flexible, armored cable extending from the 

fuse box or circuit breaker box should be connected directly 

to the junction box.

 

Locate the junction box to allow as much slack as possible 

between the junction box and the cooktop so that the 

cooktop can be moved if servicing becomes necessary 

in the future.

 

Do not cut the conduit. Use the length of conduit provided.

 

A UL Listed or CSA Approved conduit connector must be 

provided at each end of the power supply cable (at the 

cooktop and at the junction box). A listed conduit connector 

is already provided at the cooktop.

 

If the house has aluminum wiring, follow the procedure 

below:
1.  Connect the aluminum wiring using special connectors 

and/or tools designed and UL Listed for joining copper 

to aluminum.

2.  Follow the electrical connector manufacturer’s 

recommended procedure. Aluminum/copper connection 

must conform with local codes and industry accepted 

wiring practices.

WARNING

Electrical Shock Hazard

Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death, 

fire, or electrical shock.

A

A.  Model/serial/rating plate

Summary of Contents for JIC4715GS

Page 1: ...ons lectriques W11032805A COOKTOP SAFETY 1 INSTALLATION REQUIREMENTS 3 Tools and Parts 3 Location Requirements 3 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Cooktop for Installation...

Page 2: ...2 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS...

Page 3: ...hat your cooktop is approved The cooktop must be installed in a level countertop Ovens approved for this type of installation will have an approval label located on the top of the oven If you do not f...

Page 4: ...4 Product Dimensions Induction Cooktop Model JIC4715GS Top View Wok Cooktop Model JIE4115GS Top View A B A 15 38 1 cm B 21 53 3 cm A B A 15 38 1 cm B 21 53 3 cm...

Page 5: ...unit 151 8 38 4 cm 143 8 36 5 cm Two 15 38 1 cm units 301 8 76 5 cm 293 8 74 6 cm Three 15 38 1 cm units 451 8 114 6 cm 447 16 112 9 cm Four 15 38 1 cm units 601 8 152 7 cm 597 16 151 0 cm 30 76 2 cm...

Page 6: ...ustration NOTE A separate 20 amp circuit fused on both sides of the line can be used for 20 amp 2 pole breaker 240 208 volt 50 60 Hz AC supply The cooktop is rated 240 208 volts This model has a neutr...

Page 7: ...out recessed area Save the excess foam strip for use with the mounting bridge kit NOTE The foam strip helps keep the underside of the cooktop frame free from debris and helps the cooktop sit flat on u...

Page 8: ...ductor to the neutral white junction box wire 1 Disconnect power 2 Remove junction box cover if present 3 Connect the flexible cable conduit from the cooktop to the junction box using a UL Listed or C...

Page 9: ...o see which step was skipped 2 Check that you have all your tools 3 Dispose of recycle all packaging materials 4 Use a mild solution of liquid household cleaner and warm water to clean cooktop before...

Page 10: ...10 S CURIT DE LATABLE DE CUISSON...

Page 11: ...ue d incendie et vacuer ad quatement les gaz veiller acheminer l air aspir par un conduit jusqu l ext rieur ne pas d charger l air aspir dans un espace vide du b timent comme une cavit murale un plafo...

Page 12: ...enchant au dessus des unit s de surface chauff es le rangement en armoire au dessus des unit s de surface doit tre vit Si des armoires de rangement sont pr vus le risque peut tre r duit par l installa...

Page 13: ...13 Dimensions du produit Table de cuisson mod le JIC4715GS Vue de dessus Mod le JIE4115 Vue de dessus A B A 15 38 1 cm B 21 53 3 cm A B A 15 38 1 cm B 21 53 3 cm...

Page 14: ...ant la d coupe de la table de cuisson doit tre fournie selon les dimensions suivantes REMARQUE Cette option n est pas recommand e pour les comptoirs avec dosserets moul s Ne pas sceller en place l aid...

Page 15: ...ique monophas e de 240 V CA seulement 60 Hz 3 ou 4 conducteurs est requise sur un circuit s par avec protection aux deux extr mit s de la ligne par disjoncteur de 20 A 2 p les 240 208 V CA 50 60 Hz La...

Page 16: ...ace l aide de silicone Installation de la table de cuisson REMARQUE Dans le cas de l installation de plusieurs unit s une trousse d trier de montage est requise Voir la section Outils et pi ces 1 Inst...

Page 17: ...h ant 3 Avec le connecteur de conduit homologation UL ou CSA pour conduit de 1 2 13 mm connecter le conduit de c ble flexible de la table de cuisson au bo tier de connexion 4 Serrer les vis du connect...

Page 18: ...sence de tous les outils 3 liminer recycler les mat riaux d emballage 4 Avant d utiliser la table de cuisson utiliser une solution douce de nettoyant domestique et d eau ti de pour la nettoyer S cher...

Reviews: