5

Cabinet Dimensions

IMPORTANT: If installing a range hood or microwave hood 

combination above the cooktop, follow the range hood or 

microwave hood combination installation instructions for 

dimensional clearances above the cooktop surface.

Multi-Unit Dimensions

Units

Upper Cabinet 

Width (A)

Cutout 

Width (J)

One 15" (38.1 cm) unit

15"  

(38.1 cm)

14

3

/

8

(36.5 cm)

Two 15" (38.1 cm) units

30"  

(76.2 cm)

29

3

/

8

(74.6 cm)

Three 15" (38.1 cm) units

45"  

(114.3 cm)

44

7

/

16

(112.9 cm)

Four 15" (38.1 cm) units

60"  

(152.4 cm)

59

7

/

16

(151.0 cm)

30" (76.2 cm) cooktop and 

one 15" (38.1 cm) unit

45"  

(114.3 cm)

44

3

/

8

(112.7 cm)

30" (76.2 cm) cooktop and 

two 15" (38.1 cm) units

60"  

(152.4 cm)

59

7

/

16

(151.0 cm)

36" (91.4 cm) cooktop and 

one 15" (38.1 cm) unit

51"  

(129.5 cm)

50

3

/

8

(128.0 cm)

NOTE: After making the countertop cutout, some installations 

may require notching down the base cabinet side walls to clear 

the cooktop base. To avoid this modification, use a base cabinet 

with sidewalls wider than the cutout.
If cabinet has a drawer, a 5

1

/

2

" (14.0 cm) depth clearance from 

the countertop to the top of the drawer (or other obstruction) 

in base cabinet is required.

Flush Installation Dimensions

All cooktops can be mounted with a frameless standard 

installation sitting on top of the countertop surface or flush 

with the top of the countertop. If the cooktop is to be mounted 

flush with the countertop, an 

11

/

64

"-deep (4.3 mm) recessed 

area surrounding the cooktop cutout must be provided with 

the following dimensions.
NOTE: This option is not recommended for countertops with 

a molded backsplash. Do not silicone seal in place.

Multi-Unit Flush Dimensions

Units

Recessed Area 

Width (D)

Cutout 

Width (C)

One 15" (38.1 cm) unit

15

1

/

8

"  

(38.4 cm)

14

3

/

8

(36.5 cm)

Two 15" (38.1 cm) units

30

1

/

8

"  

(76.5 cm)

29

3

/

8

(74.6 cm)

Three 15" (38.1 cm) units

45

1

/

8

"  

(114.6 cm)

44

7

/

16

"  

(112.9 cm)

Four 15" (38.1 cm) units

60

1

/

8

"  

(152.7 cm)

59

7

/

16

"  

(151.0 cm)

30" (76.2 cm) cooktop and 

one 15" (38.1 cm) unit

45

1

/

8

"  

(114.6 cm)

44

3

/

8

"  

(112.7 cm)

30" (76.2 cm) cooktop and 

two 15" (38.1 cm) units

60

1

/

8

"  

(152.7 cm)

59

7

/

16

"  

(151.0 cm)

36" (91.4 cm) cooktop and 

one 15" (38.1 cm) unit

51

1

/

8

"  

(129.9 cm)

50

3

/

8

"  

(128.0 cm)

IMPORTANT: If multiple units are installed side by side, the 

mounting bridge kit W11031680 is needed for proper installation.

D

A

E

I

J

K

H

L

C

F

B

G

A.  Minimum upper cabinet width. See the “Multi-Unit Dimensions” table.
B.  Combustible area above countertop (shown by dashed box above) 
C.  30" (76.2 cm) minimum clearance between top of cooktop platform 

and bottom of uncovered wood or metal cabinet (24" [61 cm] 

minimum clearance if bottom of wood or metal cabinet is covered 

by not less than 1/4" [0.06 mm] flame retardant millboard covered 

with not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless 

steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)

D.  13" (33 cm) recommended upper cabinet depth
E. 2

5

/

6

" (5.9 cm) minimum distance to front countertop edge

F. 20

3

/

8

" (51.8 cm)

G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop 

within minimum horizontal clearances to cooktop

H.  Junction box or outlet: 7" (17.8 cm) minimum from top of countertop
I.  Junction box or outlet: 9" (23.0 cm) maximum from right side of 

cabinet

J.  See the “Multi-Unit Dimensions” table.
K.  6" (15.2 cm) minimum side wall clearance
L. 2

5

/

16

" (5.9 cm) minimum distance to rear combustible surface

D

C

A

B

E

F

E

Cooktop

Foam Strip

A.  Recessed area length 21

3

/

16

" (53.8 cm)

B.  Cutout length 20

3

/

8

" (51.8 cm)

C.  See the “Multi-Unit Flush Dimensions” table.
D.  See the “Multi-Unit Flush Dimensions” table.
E.  Recessed area depth 11/64" (4.3 mm)
F.  Recessed area radius 5/64" (2.0 mm) maximum

Summary of Contents for JIC4715GS

Page 1: ...ons lectriques W11032805A COOKTOP SAFETY 1 INSTALLATION REQUIREMENTS 3 Tools and Parts 3 Location Requirements 3 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Cooktop for Installation...

Page 2: ...2 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS...

Page 3: ...hat your cooktop is approved The cooktop must be installed in a level countertop Ovens approved for this type of installation will have an approval label located on the top of the oven If you do not f...

Page 4: ...4 Product Dimensions Induction Cooktop Model JIC4715GS Top View Wok Cooktop Model JIE4115GS Top View A B A 15 38 1 cm B 21 53 3 cm A B A 15 38 1 cm B 21 53 3 cm...

Page 5: ...unit 151 8 38 4 cm 143 8 36 5 cm Two 15 38 1 cm units 301 8 76 5 cm 293 8 74 6 cm Three 15 38 1 cm units 451 8 114 6 cm 447 16 112 9 cm Four 15 38 1 cm units 601 8 152 7 cm 597 16 151 0 cm 30 76 2 cm...

Page 6: ...ustration NOTE A separate 20 amp circuit fused on both sides of the line can be used for 20 amp 2 pole breaker 240 208 volt 50 60 Hz AC supply The cooktop is rated 240 208 volts This model has a neutr...

Page 7: ...out recessed area Save the excess foam strip for use with the mounting bridge kit NOTE The foam strip helps keep the underside of the cooktop frame free from debris and helps the cooktop sit flat on u...

Page 8: ...ductor to the neutral white junction box wire 1 Disconnect power 2 Remove junction box cover if present 3 Connect the flexible cable conduit from the cooktop to the junction box using a UL Listed or C...

Page 9: ...o see which step was skipped 2 Check that you have all your tools 3 Dispose of recycle all packaging materials 4 Use a mild solution of liquid household cleaner and warm water to clean cooktop before...

Page 10: ...10 S CURIT DE LATABLE DE CUISSON...

Page 11: ...ue d incendie et vacuer ad quatement les gaz veiller acheminer l air aspir par un conduit jusqu l ext rieur ne pas d charger l air aspir dans un espace vide du b timent comme une cavit murale un plafo...

Page 12: ...enchant au dessus des unit s de surface chauff es le rangement en armoire au dessus des unit s de surface doit tre vit Si des armoires de rangement sont pr vus le risque peut tre r duit par l installa...

Page 13: ...13 Dimensions du produit Table de cuisson mod le JIC4715GS Vue de dessus Mod le JIE4115 Vue de dessus A B A 15 38 1 cm B 21 53 3 cm A B A 15 38 1 cm B 21 53 3 cm...

Page 14: ...ant la d coupe de la table de cuisson doit tre fournie selon les dimensions suivantes REMARQUE Cette option n est pas recommand e pour les comptoirs avec dosserets moul s Ne pas sceller en place l aid...

Page 15: ...ique monophas e de 240 V CA seulement 60 Hz 3 ou 4 conducteurs est requise sur un circuit s par avec protection aux deux extr mit s de la ligne par disjoncteur de 20 A 2 p les 240 208 V CA 50 60 Hz La...

Page 16: ...ace l aide de silicone Installation de la table de cuisson REMARQUE Dans le cas de l installation de plusieurs unit s une trousse d trier de montage est requise Voir la section Outils et pi ces 1 Inst...

Page 17: ...h ant 3 Avec le connecteur de conduit homologation UL ou CSA pour conduit de 1 2 13 mm connecter le conduit de c ble flexible de la table de cuisson au bo tier de connexion 4 Serrer les vis du connect...

Page 18: ...sence de tous les outils 3 liminer recycler les mat riaux d emballage 4 Avant d utiliser la table de cuisson utiliser une solution douce de nettoyant domestique et d eau ti de pour la nettoyer S cher...