17
3.8. Connecting and disconnecting the cooling system
When
using
an annular cutter, attach the cooling system to the fitting (
1
), and then fill
the bottle with a coolant. Do not use only water as the coolant. However, using
emulsions formed from drilling oil and water is adequate. Next, open the valve
2
, and
then rotate the handle
3
and move it up-down several times to build a pressure inside
the bottle.
To
disconnect,
close
the
valve
2
,
pull
up
the release
valve
(
4
) to release excess
pressure, and then detach the cooling system from the fitting.