20
Startup codes
After connecting battery the Leviathan does a power up self check, which lasts a 1s.
It results the motor vibration or error beeps with the error log record:
1 short vibration
- All systems are OK. This vibration is about half second long.
1 short beep
- Trigger is pressed during battery connection (102)
2 short beeps
- High current flow the mosfet (106)
3 short beeps
- High temperature on the mosfet (104)
1 long beep
- Battery voltage is less than 5.5 volts (107)
2 long beeps
- Battery voltage is more than 17.0 volts (105)
3 long beeps
- High processor temperature (108)
short-long-short beep
- Motor is disconnected (109)
long-short-long beep
- Nonfunctional application (200)
Post firing codes
If any problem occurs during firing, it will be signaled by beeps with the error log record:
1 short beep
- Sector gear sensor is pressed after motor stop -> piston over traveling (100)
short-long beep
- Sector gear sensor isn‘t pressed after trigger pull (103)
2 short and long beep
- Selector plate has moved during shooting (101)
2 short beeps
- High current flow the mosfet (106)
3 short beeps
- High temperature on the mosfet (104)
1 long beep
- Battery voltage is less than 5.5 volts (107)
3 long beeps
- High processor temperature (108)
1 vibration after shot
- Battery voltage is low. If the battery drops much further, the gun
will vibrate instead firing. Now it is a good time to change your battery for new one.
1 vibration instead of fire
- Battery is discharged. The gun vibrates on every trigger pull.
change your battery for new one.
WARNING:
the battery is still slowly discharging.
1 vibration after some time
- When is delay between shot activated, it vibrates after the
time ends. It is as notification the gun is ready for shooting (sound signalization disables it)
Decreasing melody =
Wireless conn. OFF,
Increasing melody =
Wireless conn. ON